6. SPECIFICATIONS
Features
AT-8000-R
Measurement
CAT IV 600 V
Category
Operating
0 to 600 V AC/DC
Voltage
Operating
Energized: 6.25 kHz
Frequency
De-Energized: 32.768 kHz
Voltage Detection See NCV detection
Signal Indications Numeric bar graph display
and audible beep
Response Time
Smart mode: 750 mSec
Tip Sensor Energized:
300 mSec
Tip Sensor De-Energized:
750 mSec
NCV: 500 mSec
Battery monitoring: 5 Sec
Current Output of
N/A
Signal (typical)
Signal Voltage
N/A
Output (nominal)
Range Detection
Smart mode
Pinpointing: Around
(open air)
1.97-in (5 cm) radius (±2%)
Direction indication:
Up to 5FT (152.4cm) (±2%)
Tip Sensor: Energized
Pinpointing: Around 1.97-in
(5 cm) (±1%)
Detection: Up to 22-FT
(670.56cm) (±1%)
Tip Sensor: De-Energized
Detection: Up to 14-FT
(426.72cm) (±5%)
NCV (40-400 Hz)
Pinpointing: Around 1.97-in
(5cm) radius (±5%)
Detection: Up to 4-FT
(121.92cm) (±5%)
AT-8000-T
CAT IV 600 V
0 to 600 V AC/DC
Energized/Loop: 6.25 kHz
De-Energized: 32.768 kHz
> 30 V AC/DC
LEDs and audible beep
Line voltage monitoring:
1 sec
Battery voltage
monitoring: 5 sec
Energized circuit:
HI mode: 60 mA RMS
LO mode: 30 mA RMS
De-energized circuit:
HI mode: 130 mA RMS
LO mode: 40 mA RMS
Loop mode: 160 mA RMS
De-energized circuit:
LOW: 29 V RMS, 120 Vp-p
HIGH: 33 V RMS, 140 Vp-p
Loop model: 31 V RMS,
120 Vp-p
N/A
35
CT-400
CAT IV 600 V,
CAT III 1000 V
0 to 1000 V AC
Loop Mode: 6.25 kHz
High / Low Mode:
32.768 kHz
AC current measurement:
45 Hz to 400 Hz
N/A
N/A
Instantaneous
1 mA/A for AC current
measurement with
multimeter
De-energized circuit:
2.4 V RMS, 24 Vp-p
N/A