Electrical Equipment; Technical Data; Preliminary Warnings; Preliminary Checks - GiBiDi PASS Serie Instrucciones Para La Instalación

Motorreductores electromecánicos
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

PASS

ELECTRICAL EQUIPMENT [1]

1- Gearmotor: power supply,
2- Photocell transmitter 2x0.5mm² cable
3- Photocell receiver 4x0.5 mm² cable
4- Antenna screened coaxial cable.
5- Frame 4x0.5mm² cable
6- Rack
7- Key selector 3x0.5mm² cable
8- 230 Vac flashing light signaller 2x0.75mm² cable
9- Omnipolar magnetothermal switch with minimum contact opening of 3 mm. Power supply line to the control
unit: 220-230V, 50-60Hz, 3x1.5mm²

TECHNICAL DATA

Operator
Type
Supply Voltage
Power adsorbed
Current adsorbed
Thermal cutout
Capacitor
Max speed
Max torque
Torque regulation
Operating temperature
Degree of protection
Max leaf weight
Operating frequency (%)
Oil
Formula to calculate the
operating frequency
[21]

PRELIMINARY WARNINGS

Check that the gate structure is in conformity with the regulations in force and that leaf movement is linear without
friction.

Preliminary checks:

check that the gate structure is sufficiently robust. In any case, check that the weight and dimensions of the gate
Ÿ
fall within the limits of use of the operator;
3x1.5mm²
(comply with the current standards)
cable
(comply with the current standards).
PASS 600
Electronic
600 Kg
A + C
%Fu =
A + C + P
Irreversible electromechanical gearmotor
220/230Vac 50-60Hz
350W
MAX 1.5A
140°C
10µF
0,16 m/s
20 Nm
-20°C + 60°C
IP 55
60% (20°C)
GBD PH-02
A = Opening time
C = Closing time
x 100
P = Overall pause time
A+C+P = Time between two openings
UK
PASS 800
Electronic and Mechanical
800 Kg
19

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pass 600Pass 800

Tabla de contenido