1. Prepare the Site
NOTE: To simplify future servicing, install an access panel to reach
the plumbing.
NOTICE: In standard installations, locate the side valves 4" (102
mm) from the spout center, as shown in the diagram. The side
valves may be installed anywhere on the deck. Adjust the
dimensions as needed.
Determine the mounting hole locations for the spout and valves.
Refer to the roughing-in dimensions illustrated for proper
placement and diameter.
For a finished bath deck/rim less than 5/8" (16 mm) thick: Install
wood reinforcing material to the underside of the deck/rim. The
combined thickness of the reinforcing material and the deck/rim
must not exceed 3" (76 mm).
CAUTION: Risk of property damage. Select a cutting tool
appropriate for the deck/rim surface type. Refer to the
surface manufacturer's instructions for the proper cutting
procedures.
NOTICE: Do not exceed a 1-1/4" (32 mm) diameter hole for the
spout and 1-1/2" (38 mm) diameter hole for the side valves.
Maximum contact area is necessary for a successful installation.
Carefully cut mounting holes for the spout and side valves.
Install or relocate the water supplies as needed.
1205434-2-A
4
Kohler Co.