6.
Normal usage
Turn the main switch on. This will initiate the electronics.
Four dots will sequentially blink to indcate the start-up.
Next the top display will show 1P (1-phase). The lower
display shows the supply frequency 5.0 or 60 Hz.
When the start-up sequence is over, the displays shows
the active curing times in minutes. Flash-off at the upper
and full bake at the lower.
Use the + and - buttons below the displays to change
the settings. Depressing the buttons continously will rap-
idly increase the setting. Each timer can be set between
0 and 30 min. The settings will remain even after power-
off and serve as default for the next curing operation.
Start the curing by pressing the On/Off button. The ac-
tive timer will flash and the heater will switch off auto-
matically when the set times have elapsed. The cassette
fan will run for another 3 minutes for cooling down.
After idling for 30 minutes, the unit enters stand-by
mode when a dot in each display flashes. Pressing any
button will activate the unit again.
NOTES:
- The FLASH OFF timer controls the duration of the half
power output of the emitters. The FULL BAKE timer
controls the duration of the full power output of the
emitters. If both FLASH OFF and FULL BAKE timers are
used, the FLASH OFF timer will count down first and
upon switching off it will engage the FULL BAKE timer
automatically.
- To stop the unit before the time is out, press the On/
Off button.
- Altering timers is possible even during curing.
- If the temperature inside the control unit rises over
65. °C (149 °F) , the unit switches off. The upper display
will show Ot and the lower the actual temperature.
Automatic reset when the temperature falls below 5.5.
°C (131 °F) and the unit is ready for operation again.
FLASH OFF TIMER
FLASH OFF SETTINGS
FULL BAKE TIMER
FULL BAKE SETTINGS
ON/OFF BUTTON
6
Main Switch
7.
Maintenance
7.1 Filter replacement
1.
Loosen the metal clips at the
cassette side plates.
2.
Remove the used filter.
3.
Insert the new filter so that the Trisk logo is
visible from the outside.
4.
Push the long edges of the
filter into the cassette grooves.
5..
Reattach the metal clips.
Attention!
The filter is a consumable and should not be cleaned as
this will result in the loss of its filtering capacity.
7.2 IR lamp replacement
Attention!
Do not touch the aluminium reflectors or the new IR
lamp with your fingers. Remove the protective paper on
the IR lamp after you have installed it.
1. Disconnect power supply.
2. Loosen the 2 top screws on
the front plate in accordance
with Section 1.4 of the
assembly instructions.
3. Disconnect the cable connector.
4. Loosen the 4 screws on the ends
of the reflector and remove the
reflector from the plate.
5.. Remove the mesh and unscrew
the lamp from the end.
6. Install new lamps in reverse order.
CureMate 2
Metal clips
420942 rev2