TRUSST® QRG
Overview
(cont.)
Installation
Loading
Tighten/Loosen
Bolt
Installation is quick and easy, simply attach the clamp and tighten the single
bolt clockwise using a wrench until tight.
To loosen the bolt and release the clamp, remove the load and turn the bolt
counter-clockwise.
DO NOT sideload the eye bolt! Loading must be done in the plane of the eye.
°
90
°
45
CORRECT!
Load in the plane of the eye
·
When attaching a load to the CT-TENT tent clamp, all loading must be
done in the plane of the eye.
·
NEVER sideload an eye bolt! Side loading an eye bolt may cause a
failure which could cause injury or death.
·
NEVER support a person from the CT-TENT. This product is not
intended to be used as fall support/protection.
CAUTION: The maximum load capacity for the CT-TENT is 330 lb
(150 kg). DO NOT exceed this rating. Please check the specifications of the
tent before using this clamp. The Safe Working Load of the tent may be
lower than this clamp.
At maximum
4.5 in
115 mm
Eye Bolt
In-Line
°
0
4
WRONG!
Side loading of eye
EN