IMPORTANT SAFETY INSTRUCTIONS
DANGER
A person who has not read and
understood all operating
Instructions is not qualified to
operate this product.
DANGER
Do not immerse junction box in liquid.
Keep volatile or combustible material away from
junction box when in use.
Use junction box only in approved locations.
Keep sharp metal objects away from junction box.
Failure to observe these warnings may result in electric
shock, risk of fire, and personal injury.
WARNING
End-User Must Comply to the Following:
Only qualified personnel are allowed to connect
electrical wiring.
Disconnect all supply power at the source before
making any power connections.
All electrical wiring must follow local electrical
codes and highly recommend following NEC
Article 427.
The person who performs the final installation /
wiring must be qualified for this work.
The end-user is responsible for providing a
suitable disconnecting device.
The end-user is responsible for providing suitable
electrical protection device. It is highly
recommended that a ground fault circuit breaker
be used.
Failure to observe these warnings may result in personal
injury or damage to the product and/or property.
®
© BriskHeat
Corporation. All rights reserved.
PTBO-GET Octagon Hinged-Cover
Junction Box Power Connection Kit
Agency Approvals
For SLCBL -BP, -BF Series only
Class I, Div. 2 , Groups A, B, C, D
Class II, Div. 2 , Groups E, F, G
Class III
Approvals valid only when installed in accordance with
all applicable instructions, codes, and regulations.
CAUTION
Inspect all components before use.
Do not use junction box if any component is
damaged.
Do not repair a damaged or faulty component.
Do not crush or apply severe physical stress on
any component of system, including cord
assembly.
Unit must be mounted away from vibration,
impacts, water and corrosive gases.
Do not operate junction box above rated
temperature value.
Fasten junction box to device using approved
methods only.
Failure to observe these warnings may result in personal
injury or damage to the product and/or property.
3
PRODUCT OVERVIEW
The JHS-GET is designed for use with BriskHeat SLCBL / SLMCBL / SLHCBL series
heating cables in ordinary locations only.
The JHE-GET kit is approved by CSA for use in hazardous area locations with SLCBL
series heating cable only.
The PTBO-GET is rated NEMA 4X.
Earth Continuity Plate included.
SPECIFICATIONS
Operating temperatures: -40°F to 122°F (-40°C to 50°C)
Approximate volume: 38.75 in³ (635 cm³)
Material: Fire Retardant FRP Composite Polymer
Special feature: The enclosure has a uniquely designed hinged cover for added
convenience during installation.
Maximum current: 32A
Voltage: 110-120V, 208-277V
Maximum Continuous Exposure Temperature (T5): 212°F (100°C)
DIMENSIONS
®
© BriskHeat
Corporation. All rights reserved.
PTBO-GET Octagon Hinged-Cover
Junction Box Power Connection Kit
4