Service (Continued):
NOZZLES:
Nozzles should be cleaned or replaced at least
once per heating season. Contaminated fuel
could make this necessary immediately. To clean
dirt from nozzle, blow compressed air through
nozzle front. It may be necessary to soak nozzle
in clean Kerosene or diesel to help loosen any
particles (see Figure 14a and 14b).
80-OFR Nozzle
Figure 14a
125-OFR-A Nozzle
Figure 14b
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
®
MAINTENANCE (CONT.)
PHOTOCELL:
The photocell should be cleaned at least once per
heating season or more depending on conditions.
Use a cotton swab and water or alcohol to clean
the lens of the photocell.
Be certain to reinstall the photocell in proper
position as shown below (see Figure 15).
FILTERS:
The fuel filter and oil filter should be cleaned
at least twice per heating season by rinsing it in
clean Kerosene or diesel. Contaminated or old
fuel could make cleaning necessary immediately.
10
Kerosene Radiant Heater User's Manual
Figure 15
Photocell