Safety notes
Protection against scalding
It is recommended that near points of discharge with
particular sensitivity to the outlet temperature
(hospitals, schools, nursing and retirement homes)
thermostatic devices should be installed which can limit the
water temperature to 110 °F (43 °C). This product is limited
at 110 °F (43 °C). It is generally recommended that the
temperature of shower-systems should not exceed 100 °F
(38 °C) in nurseries and specific areas of care centres. Use
Grohtherm Special thermostats with special handle to facilitate
thermal disinfection and appropriate safety end stop.
Applicable standards and technical regulations for drinking
water must be observed.
Application
Thermostat mixers are designed for hot water supply via
pressurised storage heaters and, utilised in this way, provide
the best temperature accuracy. With sufficient power output
(from 18 kW or 250 kcal/min), electric or gas instantaneous
heaters are also suitable.
Thermostats cannot be used in conjunction with
non-pressurised storage heaters (displacement water
heaters).
All thermostats are adjusted in the factory at a flow pressure
of 45 psi on both sides.
Should temperature deviations occur on account of special
installation conditions, the thermostat must be adapted to local
conditions (see Adjusting).
Specifications
Safety stop
Hot water temperature at supply connection 4 °F higher than
mixed water temperature.
Thermal desinfection possible
If static pressure exceeds 72.5 psi, a pressure reducing valve
must be fitted.
Installation
Reversed connection (hot on right - cold on left).
Replace thermostatic compact cartridge, see
Replacement parts, page 10, Prod. no.: 47 175 (1/2").
Installation of the shower rail
When installing e.g. on plasterboard walls (not solid walls) it
must be assured that an appropriate reinforcement is in place
to ensure sufficient strength.
Operation
The safety stop limits the temperature range
to 100 °F (38 °C). The 100 °F (38 °C) limit can be
overridden by pressing the button, see page 4 Fig. [1].
Shut-off valves, see Fig. [2].
Adjusting
Temperature adjustment, see page 4.
Prevention of frost damage
When the domestic water system is drained, thermostat
mixers must be drained separately, since non-return valves
are installed in the hot and cold water connections. For this
purpose, the mixer must be removed from the wall.
Maintenance
Inspect and clean all parts, replace if necessary and
lubricate with special valve grease.
Shut off the hot and cold water supply.
Shut-off valves, see page 8.
Readjustment is necessary after every maintenance
operation on the shut-off valves, see Fig. [2].
Thermostatic compact cartridge, see page 9.
Readjustment is necessary after every maintenance
operation on the thermostatic compact cartridge
(see Adjusting).
Replacement parts
See page 10 ( * = special accessories).
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.
F
Consignes de sécurité
Prévention d'échaudage
Pour des points de puisage où la température de
l'eau est particulièrement critique (hôpitaux, écoles,
résidences médicalisées), il est recommandé de
systématiquement utiliser des thermostats pouvant être limités
à 43 °C (110 °F). Ce produit est limité à 43 °C (110 °F). Pour
les systèmes de douche dans les écoles maternelles et dans
certaines parties de résidences médicalisées, il est
généralement recommandé de ne pas dépasser une
température de 38 °C (100 °F). Utilisez ici des thermostats
Grohtherm Special avec poignée spéciale pour l'aide à la
désinfection thermique et la butée finale de sécurité
correspondante. Respectez les normes en vigueur ainsi que
les règlementations techniques pour l'eau potable.
100 °F (38 °C)
Domaine d'application
Les robinetteries thermostatiques sont conçues pour fournir de
l'eau chaude avec des accumulateurs sous pression et
permettent d'obtenir une température de l'eau extrêmement
précise. Si la puissance est suffisante (à partir de 18 kW,
ou 250 kcal/min), des chauffe-eau instantanés électriques ou
au gaz conviennent également.
Les thermostats ne peuvent pas être utilisés avec des
accumulateurs sans pression (chauffe-eau à écoulement
libre). Tous les thermostats sont réglés en usine sur une
pression dynamique de 3 bars. Si des différences de
température devaient apparaître, régler le thermostat en
fonction des conditions locales d'utilisation (voir Réglage).
Caractéristiques techniques
Verrouillage de sécurité
Température de l'eau chaude au raccord
d'alimentation au moins 2 °C de plus que
la température de l'eau mitigée
Désinfection thermique possible
Installer un réducteur de pression en cas de pressions
statiques supérieures à 5 bars.
Installation
Raccordement inversé (chaud à droite - froid à
gauche). Remplacer la cartouche compacte de
thermostat, voir pièces de rechange, page 10,
réf. 47 175 (1/2").
Montage de la barre de douche
En cas de montage sur un support souple, une plaque de
plâtre par exemple, s'assurer que des renforts ont été montés
sur le mur.
38 °C (100 °F)
6