Emerson dixell XW60K E T620T Instrucciones De Manejo página 14

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

XW60K
EN
STANDARD VALUES
Label Description
SEt
Set point
Hy
Differential
LS
Minimum set point
US
Maximum set point
ot
Thermostat probe calibration
P2P
Evaporator probe presence
oE
Evaporator probe calibration
P3P
Third probe presence (1st cond. probe)
o3
Third probe calibration
P4P
Fourth probe presence (2nd cond. probe)
o4
Fourth probe calibration
odS
Outputs activation delay at start up
AC
Anti-short cycle delay
AC1
Second compressor delay
rtr
P1-P2 percentage for regulation
CCt
Compressor ON time during fast freezing
CCS
Set point for continuous cycle
Con
Compressor ON time with faulty probe
CoF
Compressor OFF time with faulty probe
CF
Temperature measurement unit
rES
Resolution (integer/decimal point)
rEd
Remote display
dLy
Display temperature delay
dtr
P1-P2 percentage for disply
tdF
Defrost type
dFP
Probe selection for defrost termination
dtE
Defrost termination temperature
idF
Interval between defrost cycles
MdF
(Maximum) length for 1° defrost
dSd
Start defrost delay
dFd
Displaying during defrost
dAd
MAX display delay after defrost
Fdt
Draining time
dPo
First defrost after start up
dAF
Defrost delay after fast freezing
FnC
Fans operating mode
Fnd
Fans delay after defrost
FCt
Differential of temperature for forced activation of fans
FSt
Fans stop temperature
Fon
Fan on time with compressor off
FoF
Fan off time with compressor off
FAP
Probe selection for fan management
ACH
Kind of action for auxiliary relay
SAA
Set Point for auxiliary relay
SHy
Differential for auxiliary relay
ArP
Probe selection for auxiliary relay
Sdd
Aux.output working during defrost
ALP
Probe setting for temperature alarm
ALC
Temperature alarms configuration
ALU
MAXIMUM temperature alarm
ALL
minimum temperature alarm
AFH
Temperature alarm and fan differential
ALd
Temperature alarm delay
dAo
Delay of temperature alarm at start up
AP2
Probe for temperat. alarm of condenser
AL2
Condenser for low temperat. alarm
AU2
Condenser for high temperat. alarm
AH2
Differ. for condenser temp. alar. recovery
Ad2
Condenser temperature alarm delay
dA2
Delay of cond. temper. alarm at start up
AC2
Compr. off for condenser high temperature alarm
bLL
Compr. off for condenser low temperature alarm
tbA
Alarm relay disabling
oA3
Fourth relay configuration
AOP
Alarm relay polarity
i1P
Digital input polarity
i1F
Digital input configuration
did
Digital input alarm delay
nPS
Number of activation of pressure switch
OdC
Compress and fan status when open door
rrd
Regulation restart with door open alarm
HES
Differential for Energy Saving
PbC
Kind of probe
Adr
Serrial address
OnF
on/off key enabling
dP1
Room probe display
dP2
Evaporator probe display
dP3
Third probe display
dP4
Fourth probe display
rSE
Current set point
rEL
Software release
Ptb
Map code
Range
Default Level
LS÷US
-5
0,1÷25,5 °C / 1÷45°F
2
-50,0°C÷SET / -58°F÷SET
-50
SET ÷ 110°C / SET ÷ 230°F
110
-12÷12°C / -120÷120°F
0
n; Y
Y
-12÷12°C / -120÷120°F
0
n; Y
n
-12÷12°C / -120÷120°F
0
n; Y
n
-12÷12°C / -120÷120°F
0
0÷255 min.
0
0÷30 min.
1
0÷255s
5
0 ÷ 100 (100=P1, 0=P2)
100
0 ÷ 23h 50 min.
0
(-55.0÷150,0°C)
-5
0÷255 min.
15
0÷255 min.
30
°C ÷ °F
°C
in ÷ de
dE
P1 ÷ 1r2
P1
0 ÷ 20.0 min (10 sec.)
0
1 ÷ 99
50
EL, in
EL
nP; P1; P2; P3; P4
P2
-50,0÷110°C / -58÷230°F
8
1÷120h
6
0÷255 min.
30
0÷99 min.
0
rt, it, SEt, dEF, dEG
it
0÷255 min.
30
0÷60 min.
0
n ÷ y
n
0 ÷ 23h 50 min.
0
C-n, C-y, O-n, O-y
o-n
0÷255 min.
10
0÷50°C
10
-50,0÷110°C / -58÷230°F
2
0÷15 (min.)
0
0÷15 (min.)
0
nP; P1; P2; P3; P4
P2
CL; Ht
cL
-50,0÷110°C / -58÷230°F
0
0,1÷25,5 °C / 1÷45°F
2
nP / P1 / P2 / P3
nP
n, y
n
P1÷P4
P1
rE÷Ab
rE
-50,0÷110°C / -58÷230°F
10
-50,0÷110°C / -58÷230°F
10
0,1÷25,5 °C / 1÷45°F
2
0÷255 min.
15
0 ÷ 23h 50 min.
1,3
nP; P1; P2; P3; P4
P4
(-55 ÷ 150°C) (-67÷ 302°F)
-40
(-55 ÷ 150°C) (-67÷ 302°F)
110
[0,1°C ÷ 25,5°C] [1°F ÷ 45°F]
5
0 ÷ 254 (min.), 255=nU
15
0.0 ÷ 23h 50'
1,3
n(0) - y(1)
n
n(0) - Y(1)
n
n=no; y=si
y
ALr; dEF; Lig; AUS;
Lig
onF; Fan; db; dF2
oP; cL
cL
oP; CL
cL
EAL, bAL, PAL, dor;
dor
dEF; Htr, AUS
0÷255 min.
15
0 ÷15
15
no; Fan; CPr; F_C
F-c
n – Y
y
-30°C÷30°C; -54°F÷54°F
0
Ptc; ntc
ntc
1÷247
1
nu, oFF; ES
oFF
-
-
-
-
-
-
-
-
-
-
-
1,1
-
-
Defrost
Defrost
BY AIR
BY HOT GAS
TA
TN
TB
-
10
0
-22
Pr1
2
2
Pr2
10
-5
-25
Pr2
15
5
-18
Pr1
0
0
Pr1
n
y
Pr2
0
0
Pr2
n
n
Pr2
0
0
Pr2
n
n
Pr2
0
0
Pr2
0
0
Pr1
2
2
Pr2
0
0
Pr2
100
100
100
Pr2
0
0
Pr2
-5
-5
Pr2
0
0
Pr2
0
0
Pr2
c
c
Pr1
in
in
Pr2
P1
P1
P1
Pr2
0
0
Pr2
50
50
50
Pr1
EL
in
Pr2
P2
P2
P2
Pr1
20
20
20
Pr1
3
3
Pr1
20
20
20
Pr2
0
0
Pr2
rt
rt
Pr2
0
0
Pr2
0
2
Pr2
n
n
Pr2
0
0
Pr1
o-y
o-n
o-n
Pr1
3
3
Pr2
0
0
Pr1
40
40
40
Pr2
0
0
Pr2
0
0
Pr2
nP
P2
P2
Pr2
CL
CL
CL
Pr2
0
0
Pr2
2
2
Pr2
nP
nP
nP
Pr2
n
n
Pr2
P1
P1
P1
Pr2
re
re
RE
Pr1
5
5
Pr1
5
5
Pr2
2
2
Pr2
15
15
15
Pr2
3
3
Pr2
nP
nP
nP
Pr2
-40
-40
-40
Pr2
110
110
110
Pr2
5
5
Pr2
15
15
15
Pr2
1,3
1,3
1,3
Pr2
n
n
Pr2
n
n
Pr2
y
y
Pr2
Lig
Lig.
Lig.
Pr2
cL
cL
cL
Pr1
Op
Op
Op
Pr1
dor
dor
dor
Pr1
60
60
60
Pr2
10
10
10
Pr2
f-c
f-c
f-c
Pr2
n
n
Pr2
0
0
Pr2
ntc
ntc
ntc
Pr1
1
1
Pr2
oFF
oFF
oFF
Pr1
-
-
-
Pr1
-
-
-
Pr1
-
-
-
Pr1
-
-
-
Pr1
-
-
-
Pr2
1,1
1,1
1,1
Pr2
-
-
-
Defrost
BY HEATERS
TN
TB
0
-22
2
2
2
-5
-25
5
-18
0
0
0
y
y
y
0
0
0
n
n
n
0
0
0
n
n
n
0
0
0
0
0
0
2
2
2
0
0
0
100
100
0
0
0
-5
-5
-5
0
0
0
0
0
0
c
c
c
in
in
in
P1
P1
0
0
0
50
50
in
EL
EL
P2
P2
30
30
3
3
3
30
30
0
0
0
rt
rt
rt
0
0
0
2
2
2
n
n
n
0
0
0
o-n
o-n
3
3
3
0
0
0
40
40
0
0
0
0
0
0
P2
P2
CL
CL
0
0
0
2
2
2
nP
nP
n
n
n
P1
P1
re
RE
5
5
5
5
5
5
2
2
2
15
15
4
3
4
nP
nP
-40
-40
110
110
5
5
5
15
15
1,3
1,3
n
n
n
n
n
n
y
y
y
Lig.
Lig.
cL
cL
Op
Op
dor
dor
60
60
10
10
f-c
f-c
n
n
n
0
0
0
ntc
ntc
1
1
1
oFF
oFF
-
-
-
-
-
-
-
-
-
-
1,1
1,1
-
-

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dixell xw60k e t629Dixell xw60k e v620Dixell xw60k e cx620

Tabla de contenido