Indoor Unit
Front Panel
50mm or more from walls
(on both sides)
Outdoor Unit
• Where a wall or other obstacle is in the path of outdoor unit's intake or exhaust airflow, follow the installation guidelines below.
• For any of the below installation patterns, the wall height on the exhaust side should be 1200mm or less.
Wall facing one side
More than 50
More than 100
1200
or less
Side view
INSTALLATION DIAGRAM
30mm or more from ceiling
Service lid
M4 X 12L
• Opening service lid
Air fi lter
Service lid is opening/closing
type.
• Opening method
1) Remove the service lid
screws.
2) Pull out the service lid
diagonally down in the direction
of the arrow.
3) Pull down.
INSTALLATION OF THE OUTDOOR UNIT
Caulk pipe
hole gap
with putty.
Walls facing two sides
More than
100
M
o
e r
h t
a
n 50
Top view
Walls facing three sides
More than 50
Top view
1-5
Cut thermal insulation pipe to
an appropriate length and wrap
it with tape, making sure that no
gap is left in the insulation pipe's
cut line.
.
Wrap the insulation pipe with the
fi nishing tape from bottom to top.
More than 150
M
o
e r
h t
More than 150
More than 300
unit: mm
a
n 50