Ratings
Input 24 V DC, max. 65 W (65 VA)
ƒ
Max. ambient temperature 40 °C
ƒ
Environmental ratings: Type 1 Enclosure
ƒ
Optional communication ratings:
ƒ
–
RS232−Connection: max. 3 A
–
USB−Connection, PS/2−Connection: max. 1 A
–
LAN−Connection: Standard ISDN or RJ45
–
VGA−Connection, FBAS−Connection, DVI−Connector, DPL−Connection:
max. 4 A
–
External Power Supply for DVI/USB Extender: max. 4 A
–
Video−DSUB Connection for DVI/USB Extender: max. 4 A
–
Data−DSUB Connection for DVI/USB Extender : max. 4 A
O
Warnings!
Conditions of acceptability
ƒ
ƒ
ƒ
ƒ
Field Wiring Markings
Wiring Terminal MSTB 2,5/3−STF−5,08:
ƒ
ƒ
ƒ
MA_CSx0xx DE/EN/FR/ES/IT 2.0
Sicherheitshinweise für die Installation nach UL
These devices are evaluated to meet environmental UL Type 1
Enclosure requirements, when all openings in the enclosure back
are closed (filled) by devices with suitable environmental type
ratings. This may be achieved by use of appropriate supporting
beam (support arm system), with suitable environmental ratings
or equivalent means.
Models CS5710 IPC and CS5710 DVI are rated for environmental
UL Type 1 Enclosure, when openings in the front are closed with
suitable devices (e.g. buttons, emergency off button, etc.).
The effects of condensation or high humidity shall be reduced by
the application of heat through continuous energization of the
equipment, with interruptions such that cooling to the point of
condensation does not occur.
The devices are intended for the use in a pollution degree 2 or
controlled environment only.
Use Copper Wire only.
AWG 18 ... AWG 12 (0.82 mm
Torque 5...7 lb−in (0.5 ... 0.6 Nm)
l
Sicherheitshinweise
2
2
... 3.3 mm
)
2
7