Safety
Important Safety
Instructions
PLEASE READ ENTIRE INSTRUCTIONS
BEFORE PROCEEDING
Natural Gas to Propane (LP) Gas Conversion Kit for
Thermador Professional
Ranges
FOR RESIDENTIAL USE ONLY
IMPORTANT:
Only a qualified service technician or installer should make
this conversion.
INSTALLER:
Please leave these Conversion Instructions with this unit
for the owner.
OWNER:
Please retain these instructions for future reference.
®
Contains Star
Burner orifices for proper conversion to
Propane Gas operation for all burners in cooktop or
rangetop section of the following series models.
Save the natural gas parts for possible conversion from LP
back to the natural gas in the future.
This kit is used to convert Thermador Professional
Cooktops and PRO-HARMONY™ Dual-Fuel Ranges from
natural gas to Propane (LP) Gas operation. This kit cannot
be used to convert older models of Thermador Professional
cooktops or ranges (see TABLE 2). This kit cannot be used
to convert Thermador Professional
burners, or any other brand of appliance.
®
Cooktops and Dual Fuel
®
®
All Gas Ranges, oven
WARNING:
This conversion kit shall be
installed by a qualified service
agency in accordance with the
manufacturer's instructions and all
applicable codes and requirements
of the authority having jurisdiction.
If the information in these
instructions is not followed exactly,
a fire, explosion or production of
carbon monoxide may result
causing property damage,
personal injury or loss of life. The
qualified service agency is
responsible for the proper
installation of this kit. The
installation is not proper and
complete until the operation of the
converted appliance is checked as
specified in the manufacturer's
instructions supplied with the kit.
CAUTION:
Disconnect gas and electric power before
making conversion. Before turning power ON,
be sure that all controls are in the OFF position.
To the Service Agent:
It is important that you know the following BEFORE you
begin the gas conversion of the appliance.
•
Confirm that the Propane (LP) Gas supply system is
available and ready to use. This is particularly
important for new construction.
•
You must plan for sufficient time and resources to
perform the LP conversion process properly and
completely before leaving the job site. Every step
described in these instructions must be performed to
safely convert the appliance for proper operation on
Propane Gas. INCOMPLETE OR INADEQUATE GAS
CONVERSION OF THE APPLIANCE CAN CREATE A
SAFETY HAZARD.
English 1