Despite the use of these two systems, the energy delivered to the electrical fitting remains within the given tolerance according to
ISO 12176-2. In order to avoid damage to the machine and to ensure that the internal systems of functions control do not break the
fusion cycle, the motor generator should be conform to the following recommendations:
is suitable to operate inductive loads and operating systems with phase "cut" (some generators have the voltage
regulating system that does not allow phase "cut") to the connected equipment;
keep a stable output voltage and the motor rotation speed even in the presence of quickly alternating loads;
the peak-peak voltage must not exceed 800 Volts
adjustable gap voltage (AC) between 240V-260V (230V nominal)
provides a minimum power according to the following table:
20) Warning on generators use
Turn on the generator, when it will be stable insert ECU plug into the electrical outlet.
Do not connect other machines or electrical equipment to the generator when the ECU is connected.
Unplug ECU before turning off the generator.
The efficiency of the generator will decrease by 10% every 1000m in height.
Check the fuel level before starting the fusion process.
Minimum output power
Type of
Fitting diameter
control unit
(mm.)
20-75
90-160
I Plast 105
180 – 500
560-1200
20-75
90-160
I Plast 60
180-400
20-75
I Plast 60
90-160
Estimated output power
(kW)
2,0
3,2
5,0
7,0
2,0
3,2
5,0
2,0
3,2