Trouble Shooting; Updating The Chart Carrier - Siemens VDO MTCO 1324 Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
Displayed messages

Trouble shooting

Only after having remedied the error cause,
e.g. in case of an operating error, will the
message automatically be deleted.
In case one of the messages is shown
repeatedly, immediately consult a
Siemens VDO service partner!
34
Code
Meaning / measure
9061
= Error in recording system
9062
(The MTCO will record these errors on the chart,
➥ see page 39.)
9 0 63
9 4 30
= Error at "B7" v-pulse output
A 4 11
= Disconnection towards indicating instrument
A423
=
Error during pulse generator communication
A 8 22
=
Error in pulse generator key / serial number /
signal
(The MTCO will record these errors on the chart,
➥ see page 39.)
A 4 00
= Power loss
(Error code cannot be found in the error memory.
The MTCO will record a power loss on the chart,
➥ see page 39.)

Updating the chart carrier

 Open the drawer and remove both
charts.
 Close the drawer again.
½ The MTCO will automatically update
the time of the chart carrier, and the
error symbol and the time will then
stop to flash.
 Open the drawer and insert new charts if
necessary. The MTCO 1324 will be ready
for use again.
Kienzle MTCO 1324

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido