TROUBLESHOOTING
Problem
Engine is running, but
no AC output is
available.
Engine runs good but
bogs down when
loads are connected.
Engine will not start;
or starts and runs
rough.
Engine shuts down
during operation.
Engine lacks power.
Engine "hunts" or
falters.
PowerBoss 4,500 Watt Contractor Generator
Cause
1.
Circuit breaker is open.
2.
Poor connection or defective cord set.
3.
Connected device is bad.
4.
Fault in generator.
1.
Short circuit in a connected load.
2.
Generator is overloaded.
3.
Engine speed is too slow.
4.
Shorted generator circuit.
1.
Engine switch set to "Off".
2.
Low oil level.
3.
Dirty air cleaner.
4.
Out of gasoline.
5.
Stale gasoline.
6.
Spark plug wire not connected to
spark plug.
7.
Bad spark plug.
8.
Water in gasoline.
9.
Overchoking.
10. Excessively rich fuel mixture.
11. Intake valve stuck open or closed.
12. Engine has lost compression.
1.
Out of gasoline.
2.
Fault in engine.
1.
Load is too high.
2.
Dirty air filter.
3.
Engine needs to be serviced.
1.
Choke is opened too soon.
2.
Carburetor is running too rich or too
lean.
Solution
1.
Reset circuit breaker.
2.
Check and repair.
3.
Connect another device that is in good
condition.
4.
Contact Generac service facility.
1.
Disconnect shorted electrical load.
2.
See "Don't Overload the Generator" on
page 11.
3.
Contact Honda service facility.
4.
Contact Generac service facility.
1.
Set switch to "On".
2.
Fill crankcase to proper level.
3.
Clean or replace air cleaner.
4.
Fill fuel tank.
5.
Drain gas tank and fill with fresh fuel.
6.
Connect wire to spark plug.
7.
Replace spark plug.
8.
Drain gas tank; fill with fresh fuel.
9.
Set choke to "Off" position.
10. Contact Honda service facility.
11. Contact Honda service facility.
12. Contact Honda service facility.
1.
Fill fuel tank.
2.
Contact Honda service facility.
1.
See "Don't Overload the Generator" on
page 11.
2.
Replace air filter.
3.
Contact Honda service facility.
1.
Move choke to halfway position till engine
runs smoothly.
2.
Contact Honda service facility.
15