Electrical Connections - Perry TE526 Manual Del Usuario

Termostato digital de superficie
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3 - INSTALLATION

3.4 - ELECTRICAL CONNECTIONS

Important: the installation and electrical connection of the devices and appliances must be implemented by qualified personnel and in confor-
mity with current laws and regulations. The manufacturer declines all liability in connection with the use of products subject to special environ-
mental and/or installation standards.
Disconnect the 230V~ mains voltage
“connect the device that is to be controlled to the terminals:
1 - common
2 -
normally closed contact
3 -
normally open contact
Examples of electrical connections
Connection to a boiler
NO
C
NC
BOILER
3
2
1
L
230V~
N
230V~
6 7 8 9
Contact to control
the thermostat
Telephone programmer
“a telephone programmer can be connected to terminals
8
and
9
so as to activate the thermostat from a distance
(see example in the wiring diagram) and follow telephone
programmer instructions.
Connection to a motorized valve
NO
N L
NC
LOAD
opens
3 2 1
M
closes
C
6 7
8 9
Contact to control
the thermostat
Telephone programmer