5.7 - PROPORTIONAL CYCLE DURATION
The duration of the control cycle for the PROPORTIONAL mode
(
)
can be set from
7
recommended for systems with high thermal inertia (cast iron
radiators, floor systems) and a short cycle for systems with low
thermal inertia (fan coils). The default setting is
Mode
OK
Mode
OK
Mode
OK
to
20
minutes. A long cycle is
10
minutes.
Set the duration of the
proportional control cycle
via the
or
button.
Press
OK
to save and move
on to the subsequent
setting or keep the button
pressed for at least 4 sec to
save the new setting and
exit the programming
menu.
5.8 - ADJUSTING OR EXCLUDING THE ANTI-FREEZE PROTECTION
When set to the
mode, the thermostat is set to protect the system
in the event of frost, when the temperature falls below +4.0 °C; this
setting can be adjusted from +4.0 °C to +12.0 °C. This function can
also be excluded. In this case, the system will be exposed to possible
damages caused by frost.
Mode
OK
Mode
OK
Mode
OK
1°
Set the desired anti-
freeze temperature via
the
or
button.
Press
OK
to save and
move on to the subsequent
setting or keep the button
pressed for at least 4 sec to
save the new setting and
exit the programming
menu.
If on the other hand you
wish to exclude the anti-
freeze protection, press
the
or
button until
appears on the
display and confirm via
t h e
O K
b u t t o n a s
described above.