Radiator with electronic
thermostat
IRSAP SPA
45031 Arquà Polesine (RO) Italy
Tel. +39 0425 466611 - Fax +39 0425 466662
Website: http://www.irsap.com
E-mail: info@irsap.it
----------------------------------------------------------
IR GROUP SARL
19,Chemin de la Plaine 69390 Vourles (France)
Tel. +33 04 28 00 01 67 - Fax +33 04 72 31 86 40
Web: http://www.irsap.com;
E-mail: irsaprhoss@irgroup.fr
----------------------------------------------------------
IRSAP-RHOSS Clima Integral, S.L.
Oficina y Almacèn: P.I.CAMI RAL
Leonardo da Vinci,4 08850 Gavà (Barcelona)
Tel. 93 633 47 00 - Fax 93 633 47 04
E-mail: www.informacion@irsap.com
www.irsap.com
----------------------------------------------------------
IRROM Industrie S.R.L.
Str. Pricipalà 1/A, Sat Fundàtara, Iclod 407336,
jud. Cluj, Romània
Tel: +40 (0)264 263400 - Fax: +40 (0)264 263404
Web: www.irsap.ro
The Towel Warmer radiator is an electrical appliance endowed with the following features:
• Voltage-feed 230V 50Hz, 1ph
• Insulation Class II
• Protection degree IP44
• Length electrical cable 1200 mm
• Electronic ambient thermostat .
The association between electrical heater and the radiator model allows a radiator surface temperature no higher than about 70°C
The Towel Warmer radiator is filled in the factory with a measured quantity of a special liquid, to optimize the heat transmission.
Because of this, any repairs which require the opening of the towel-rail, must be executed from the manufacturer.
This applies equally in the unlikely event of the special liquid leaking out of the towel-rail.
The thermostat can work exclusively when paired with a specially prepared electric heating element, equipped with safety devices to limit excess
temperature and make the system safe in the event of abnormal factors (see Warnings).
The radiator must be installed by qualified staff .
Always fix the heated Towel Warmer to the wall as per the assembly instructions enclosed.
The installation must be carried out by a specialized firm in compliance with the standards in force.
IEC 364-7-701 1984
and subsequent editions
To supply the tower rail radiator, an omnipolar switch, with at least 3 mm of distance between contacts, must be employed.
When installing in bathrooms or in shower-rooms, the appliance should be installed in such a way to avoid the switch and other controls to be
reached by people using the bathroom or the shower. (see Fig. B)
The radiator must not be installed immediately beneath a fixed current outlet.
Take utmost care while installing the Towel Warmer radiator to avoid damaging the electronic thermostat and the connecting cable. If the cable is
da-maged the replacement must be done by the manifacturer, by technical autorized service or by someone with the some professional qualification
to prevent any risk.
The radiator must be kept out of the reach of children less than three years old unless they are constantly supervised in its presence.
Children from 3 to 8 years old can only switch the device on or off, provided that it has been positioned or installed in the position normally
envisioned and that the children are under supervision or that they have been instructed in the use of the device in complete safety and awareness
of all the potential risks. Children from 3 to 8 years old must not connect, adjust, or clean the device or perform user maintenance operations. The
device cannot be used by children less than 8 years old, by people with reduced physical, sensorial, or mental ability, or by people without
experience or the necessary knowledge unless they are supervised during use or they have been instructed in the use of the device in complete
safety and awareness of all the potential risks. Children must never be allowed to play with the device. User cleaning and maintenance operations
must never be performed by children without supervision. Connect the device to the power supply only after first fastening the radiator to the wall.
It is absolutely forbidden to:
• supply power to the control BEFORE HAVING CHECKED THAT THE THERMOSTAT IS CORRECTLY INSTALLED ON THE RADIATOR.
• cut the power supply cable to disconnect the appliance;
• damage the power supply cable. If the power supply cable is damaged, the entire electric heater must be replaced by the manufacturer or by one
of the manufacturer's service centres or anyhow by a person with similar qualifications, to avoid any risks.
• Make sure that the radiator has been completely filled with water before switching on the electric heater.
Warning: The surfaces of the radiator are hot during operation.
WARNING - Certain parts of this product can become extremely hot and cause burns. Special attention must be paid whenever children and
vulnerable adults are present.
It is normal for the two lower pipes to be tepid during operation.
In order to avoid every risk to the smallest children, we recommend installing the device in such way that the lowest heating pipe is at least 600 mm
above the ground.
WARNING:
Only water-washed clothes can be dried on a towel warmer radiator.
Do not clean with corrosive or abrasive products.
Cod. 843M0216
Fig. B
ENGLISH (UK)
TECHNICAL FEATURES
HEATING ELEMENT TECHNICAL CHARACTERISTICS
INSTALLATION
norms must be complied when installing the towel rail.

DIRECTIONS FOR USE

Fig.A