Main Functions; Alarm Set - TZS First AUSTRIA FA-2461 Manual De Instrucciones

Tabla de contenido

Publicidad

oPerAtion instruction

1. MAin Functions:

1. Weather forecast for 4 states: sunny, semi-
sunny, cloudy, rainy
2. seven function keys: sEt, alarM, ch,MaX/
Min, up, doWn/cF, snooZE/light.
3. seven languages to show the day: English,
germany, French, italian, spanish, dutch,
danish
4. 6 digit time display: hour, minute, second
5. temperature display format selectable (°c/°F),
12/24 hour selectable
6. calendar indication: 2000-2099
7. indoor temperature range: 0-50℃, sampling
cycle: 15 seconds
8. indoor humidity range: 20-95%, sampling cycle:
15 seconds
9. outdoor temperature/humidity with rF: up to 3
channels
10. in/out trend indication of temperature/humidity
11. indication of the comfort index
12. the function of alarm/snooze
13. Moon phase
2. PoWer-on And reset
1. When power-on and reset, lcd full display for
3 seconds  enter the normal state after "Beep"
 check temperature and humidity
2. the calendar defaults 0:00 January 1, 2007
3. alarm defaults 0:00
4. time system defaults 24hr.
5. the weather icon defaults semi-sunny
6. Temperature scales defaults Celsius degree ℃.
3. instruction oF oPerAtinG the
keys
3.1 key functions (see table)
3.2 normal states
1. hold "sEt" to enter into time setting
2. click "alarM" to switch the alarm on/off
3. hold "alarM" for 2 seconds to enter into alarm
setting
4. click "up" to switch between 12hr/24hr
5. press "doWn/cF" to switch between °c/°F
6. click "MaX/Min" to switch Maximum/Minimum
temperature and humidity
7. hold "MaX/Min" for 2 seconds to clear the
history record of temperature and humidity
8. When alarM rings, click "snooZE/light" to
enter into the snooze state every 5 minutes
9. click "snooZE/light" the backlight will be on
for 5 seconds
10. press "ch" to switch rF channel, ch1  ch2
 ch3
11. hold "ch" key for 2 seconds to clear out all data
of current channel
3.3 time set
1. hold "sEt" key for 2 seconds to enter into time
setting
m_2461_kl_v03.indd 2-3
2. the sequence of time setting: World time Zone
hour Minute Year  Month  date 
language  Exit
3. There will have 1Hz flashing during setting
4. Press "SET" to confirm the setting, and enter the
next setting state
5. press "up" one time, the setting will go ahead
for one step; hold the key for 2 seconds, it will
run forward by 8 steps/second.
6. press "doWn/cF" one time, the setting will
backward for one step; hold for 2 seconds, it will
run back by 8 steps/second.
7. Moon phase is changed accordingly the
changing of month and date
8. the system will exit automatically if no key is
operated in 8 seconds.

3.4 Alarm set

1. hold "alarM" key for 2 second to enter into
alarm setting
2. the sequence of alarm setting: hour  Minute
 Exit
3. There will have 1Hz flashing during setting
4. Press "ALARM" to confirm the setting, and enter
the next setting state
5. press "up" one time, the setting will go ahead
for one step; hold the keys for 2 seconds, it will
run forward by 8 steps/seconds.
6. press "doWn/cF" one time, the setting will
backward for one step; hold for 2 seconds, it will
run back by 8 steps/second.
7. the system will exit automatically if no key is
operated in 8 seconds.
4. Function And eFFect
4.1 the receiving function of rF
1. after installing the battery and checking
temperature/humidity, it will enter rF receiving
state automatically for 3 minutes.
2. under normal display mode, hold the "ch"
key for 2 seconds to clear out the channel
information
3. if there is no effective signal with same id code
received for the current channel in 35 minutes,
the temperature of that ch will shows "--. -".
4. the temperature display will resume back when
the correct signal is received again
4.2 the function of alarm
1. the BuZZEr will ring for 2 seconds as below:
a. 0-10 sec.: one "beep" per second
b. 10-20 sec.: two "beep" per second
c. 20-30 sec.: four "beep" per second
d. after 30 sec.: "beep" continuously
2. When ringing, click "snooZE/light" key once
to enter into 5 minutes snooze states, exit if any
other key is clicked.
4.3 the function of temperature and humidity
1. the indoor temperature display range: 0- +50℃
(32- +122℉)
2. the indoor & outdoor humidity range: 20-95%
3. sampling period: 15 seconds.
2
4.4 the function of weather forecast
Weather icons for 4 states: sunny  semi-sunny 
cloudy  rainy
4.5 trend indicator:
the trend pointer displayed on the lcd indicates
the trend of the indoor temperature:
1. the difference between current temperature and
recorded temperature is more than +1°c, the
trend shows c.
2. the difference between current temperature
and recorded temperature is less than -1°c, the
trend shows a
3. When the change of temperature is within
+/-1°c, the trend shows B
the comfort – level icons:
coMFort leVel
icon disPlAy
teMPerAture rAnGe
L
drY
-5°c to +50°c
coMFort
J
+20°c to +28°c
K
WEt
-5°c to +50°c
no indication
-
K
less than 20°c or more than 28°c
key functions:
operation
Function set
Alarm
up
down/cF
standard
click
-----
alarm
12hr/24hr
°c/°F
mode
on/off
switchable
switchable
hold
Enter
Enter
-----
-----
into clock
into
setting
alarm
setting
time set
click
Confirm
-----
one step
one step
the setting
forward
backward
hold
-----
-----
8 steps/
8 steps/
second
second
forward
backward
alarm set
click
-----
Confirm
one step
one step
the
forward
backward
setting
hold
-----
-----
8 steps/
8 steps/
second
second
forward
backward
4.6 the comfort – level icons:
see table
seven language For your reference:
huMidity rAnGe
under 40%
40% to 70%
over 70%
less than 40% or more than 70%
snooze/light
ch
MAX/Min
Backlight/Enter into
switchable
display the max/
snooze state
between
min temperature
ch 1, 2, 3
and humidity
-----
clear current
delete the max/
registered ch
min temperature
and humidity
record
Backlight
-----
-----
-----
-----
-----
Backlight
-----
-----
-----
-----
-----
3
10/15/12 2:30 pM

Publicidad

Tabla de contenido
loading

Tabla de contenido