BA230
ELECTRICAL CONNECTIONS: FASTONS
1
CF1 CF3
2
CF2 CF4
3
CF5 CF6
4
CF7 CF8
5
CF9 CF10
ELECTRICAL CONNECTIONS: TERMINAL BOARDS
Terminal
Position
1
JP1
2
3
4
5
6
7
JP2
8
9
10
11
12
13
14
15
JP5
16
17
18
19
20
21
JP4
22
23
24
Primary connection of 230 VAC transformer (black cables)
Secondary connection of 14 VAC transformer (red cables)
Secondary connection of 22 VAC transformer (blue cables)
Motor 2 capacitor connection
Motor 1 capacitor connection
Signal
Description
PHASE
230 VAC power supply.
NEUTR
230 VAC power supply.
Ground wire connection.
GND
Flashlight output 230 VAC 40W.
LAMP
Flashlight output 230 VAC 40W.
LAMP
Motor 1 connection (closing).
CLOSE
COM
Motor 1 common.
Motor 1 connection (opening).
OPEN
Motor 2 connection (closing).
CLOSE
COM
Motor 2 common.
Motor 2 connection (opening).
OPEN
Electric lock negative.
COM
EL1
Electric lock +12 Vdc positive - motor 1.
EL2
Electric lock +12 Vdc positive - motor 2.
External accessory power supply negative.
GND
WARNIN
Warning light output - 24 VAC 3W
G LIGHT
max.
+24 Vdc external accessory power supply (photocells, radio, etc.)
24Vdc
+24 Vdc external safety device power supply.
SEC
START input (N.O.)
START
PED
PEDESTRIAN input (N.O.)
STOP input (N.C.)
STOP
If not used, jumper with terminal 31.
Opening limit switch input - motor 1 (N.C.).
FCAM1
If not used, disable during programming by enabling the C10 menu.
Closing limit switch input - motor 1 (N.C.).
FCCM1
If not used, disable during programming by enabling the C10 menu.
Opening limit switch input - motor 2 (N.C.).
FCAM2
If not used, disable during programming by enabling the C10 menu.
Operation:
slow flashing during opening, off during
pause, fast flashing during closing.
Operation:
slow flashing during opening, on fixed during
pause, fast flashing during closing.
SLIDING GATE CONFIGURATION:
opens for the time set in the H10 menu.
SWING GATE CONFIGURATION:
fully opens gate 1.