MENU F: FORCE AND SPEED ADJUSTMENTS
Menu
Function
F1
MOTOR 1 FORCE
DECELERATION
F2
FORCE MOTOR 1
F3
MOTOR 2 FORCE
DECELERATION
F4
FORCE MOTOR 2
MENU H: TIME ADJUSTMENT
All the times can be set in steps of 1 second.
Menu
Function
H1
MOTOR 1 OPENING TIME
H2
MOTOR 1 CLOSING TIME
H3
MOTOR 1 DECELERATION TIME
H4
MOTOR 2 OPENING TIME
H5
MOTOR 2 CLOSING TIME
H6
MOTOR 2 DECELERATION TIME
GATE 2 PHASE SHIFT TIME
H7
DURING OPENING
H8
GATE 1 PHASE SHIFT TIME
DURING CLOSING
AUTOMATIC CLOSING
H9
PAUSE TIME
H10
PARTIAL OPENING TIME
PEDESTRIAN AUTOMATIC
H11
CLOSING TIME
H12
NUMBER OF CYCLES
H13
INSTALLER CODE
H14
SOFTWARE VERSION
Description
Adjusts the thrust of motor 1.
0001 = minimum force
0010 = maximum force
NB. HYDRAULIC OPERATORS, SET MAXIMUM VALUE
Adjusts the thrust of motor 1 during deceleration
0001 = minimum force
0010 = maximum force
Adjusts the thrust of motor 2.
0001 = minimum force
0010 = maximum force
NB. HYDRAULIC OPERATORS, SET MAXIMUM VALUE
Adjusts the thrust of motor 2 during deceleration
0001 = minimum force
0010 = maximum force
Description
Gate 1 opening time.
Gate 1 closing time.
Gate 1 operating time in deceleration mode.
Gate 2 opening time.
Gate 2 closing time .
Gate 1 2 operating time in deceleration mode.
Delays the start of opening of gate 2 with respect to gate 1.
In the case of a configuration with double sliding gate, the time H7 is
automatically cancelled.
Delays the start of closing of gate 1 with respect to gate 2.
In the case of a configuration with double sliding gate, the time H8 is
automatically cancelled.
Determines the pause time during opening before automatic closing.
Determines the pedestrian opening time for the sliding gate only.
Determines the pause time during pedestrian opening before automatic closing.
Allows setting a number of cycles (opening + closing) before the maintenance
request Signalled by the light flashing for 5 minutes after the end of each
manoeuvre. The value set will always be multiplied by 10.
Allows entering the installer code to customise the settings during programming.
CAUTION: An already stored code can be cancelled by typing in the factory
code '0000' when requested to access programming.
In this way, however, all the existing settings are cancelled and the default
settings automatically loaded.
Shows the version of the firmware installed on the board.