T116KB/
T116KBP
Maintenance
1.
Lightly oil the Cutter assembly pins
as needed.
2.
Check the pressure regulators for water.
The pressure regulator have glass water
traps. It is important to periodically
remove any water that has accumulated.
3.
Check the regulator for correct pressure.
Set the left regulator (connected to the
Cutter assembly) to 70-80 PSI. Set the
right regulator (connected to the treadle
assembly) to 30-40 PSI. ake sure the
regulators are locked to keep the
pressure from changing.
4.
Check the reflective tape for wear. If it
appears worn or damaged, replace it.
5.
The entire sewing machine should be air
cleaned after each shift.
16
(770)963-7369 F X (770)963-7641
TL NT
TT CHMENT COMP NY
401 Industrial Park Dr.-Lawrenceville, G . 30045
Mantenimiento
1.
Aceite los pasadores de la Cortadora
ligeramente cuando lo necesiten.
2.
Chequee los reguladores de la presión por
agua. El regulador de presión tiene unas
trampas del agua de vidrio. Es importante
remover periodicamente cualquier agua que se
ha acumulado.
3.
Chequee el regulador por presión correcta.
Ponga el regulador izquierdo (conectado al
ensamblado de la Cortadora) a 70-80 PSI (Lbs.
por pulgada cuadrada) Fije el regulador de la
derecha (conectado al pedal) a 30-40 PSI
Asegurese que los reguladores tienen seguro
para evitar que la presión cambie.
4.
Chequee la cinta reflectora por desgaste. Si
parece desgastada o dañada, reemplacela.
5.
Toda la máquina de coser debe ser limpiada
con aire a presión despues de cada turno.
T116KB /
T116KBP