Parts LIst
Mounting bracket .................................................................................................. 1
Screws ................................................................................................................ 4
Wall anchor ........................................................................................................... 4
INstaLLatIoN
Tools required:
• Electric drill
• Phillips (cross-head) screwdriver
• Tape measure
Choose a suitable location for mounting the convector:
A. The location shall have enough space and clearance as illustrated in Fig. 1.
B. The power outlet shall be accessible by the electrical cord of this convector without
using an extension cord.
C. The power outlet shall not be located directly behind or above the convector.
WIDTH OF CONVECTOR
9.8 cm
33.7 cm
6 in
(15.3 cm)
Minimum
clearance to
adjacent
surface
22.2 cm
6 in
(15.3 cm)
Fig. 1
waLL MoUNtING INstrUCtIoNs
1. Release the mounting bracket by pressing the locking brackets on both sides.
2. Use the mounting bracket as a template by holding it against the wall as illustrated
in Fig. 1.
3. Follow the dimensions specified in Table 1 and place mounting bracket in the
desired location.
4. Mark the 4 screw holes. Place mounting bracket on the screw markings and ensure
the mounting bracket is perfectly level.
5. Predrill holes and insert 4 wall anchors. Wall anchors are needed for mounting on
drywall or concrete walls. Ensure you use the proper anchors for your wall type.
6. Replace the mounting bracket and fasten it with screws (minimum 4 screws).
7. Mount the convector to the mounting bracket and engage the 2 locking brackets at
the top. See Fig. 2.
CAuTION – hIgh TeMPeRATuRe, RIsk Of fIRe. keeP eleCTRICAl CORds,
dRAPeRy, fuRNIshINgs ANd OTheR COMbusTIbles AT leAsT 3 fT (0.9 M)
AWAy fROM The fRONT Of The heATeR ANd AWAy fROM The sIde ANd Of
heATeR.
WARNINg – TO ReduCe RIsk Of fIRe, dO NOT sTORe OR use gAsOlINe OR
OTheR flAMMAble VAPORs ANd lIquIds IN The VICINITy Of The heATeR.
58.1 cm
14.6 cm
6 in
(15.3 cm)
Minimum
clearance to
adjacent
surface
22.2 cm
Minimum
distance
to ground
Wall bracket
Wall
Fig. 2
oPeratIoN
Turn the "0/I" switch on the right side of the convector to "I" position. The indicator light
and display will be ON.
1. Time setting – Press MODE button and press UP and DOWN buttons at the same
time.
A. Press the UP or DOWN button to set the 'DAY' from MONDAY (MO) – TUESDAY
(TU) – WEDNESDAY (WE) – THURSDAY (TH) – FRIDAY (FR) – SATURDAY (SA) –
SUNDAY (SU).
B. Press MODE button again. The display 'HOUR' will flash and then press the UP or
DOWN button to set the 'HOUR'.
C. Press MODE button again. The display 'MINUTE' will flash and then press the UP
or DOWN button again to set the 'MINUTE'.
D. Press MODE button again to exit and save the setting.
2
Convector