FriWa
4.9
Balance value
BalancEs
4.10
Emergency operation
Options/emergency
Adjustment range Yes ... No
Factory setting No
Settings/Emergency
Adjustment range 12...100%
Factory setting 100%
4.11
Manual operation
Manual Operation
Adjustment range Off,Auto, On
Factory Setting Auto
4.12
Switching off the controller externally
options/extern off
Adjustment range Yes ... No
Factory setting No
4.13
Energy quantity (heat quantity)
Balances
Following values are balanced:
- operating days regulation
- tap quantity (cold water supply)
- major volume flow
- operating hours loading pump (P1)
- operating hours circulation pump (PC)
- minimum temperature of the source (T-S)
- maximum temperature of the source (T-S)
- minimum temperature cold water (T-CW)
- maximum temperature cold water (T-CW)
- intergrated energy in hot water circuit
(see heat quantity)
Due to this option the pump can be set to a fixed pump
level in continuous operation.
The pump speed during emergency service can be adjus-
ted.
Each relay can be switched off and on by means of manual
operation.
By means of input S9 the controller can be switched off.
This means that the fresh water processing, circulation
function, blocking protection, emergency service and re-
turn flow will be suppressed. The manual operation mode
at the controller will flout the external control signal.
By means of the measured volume flow, the domestic cold
and hot water and hot temperature the energy quantity
can be measured.