in this information.
1.8.3) If the user has the slightest doubt about the
efficiency of the device shall replace it immediately,
particularly after using it to stop a fall.
1.8.4) This device shall only be used by users
medically fit, trained (and educated) for use or
under direct control of trainers / supervisors.
1.8.5) Rock and ice climbing, descents and abseils,
the "via ferrata", speleology and caving, ski-
mountaineering, canyoning, exploration, rescue,
tree climbing and work at height are all high-risk
activities that may involve even fatal accidents. The
user assumes all risks arising from the practice of
these activities and the use of all our devices.
1.8.6) Laboratory tests, checks, inspections, informa-
tion and standards do not always succeed to repro-
duce the practice, so the results obtained in real life
conditions of use of the device may sometimes differ
significantly. The best indications are provided by the
continuous use and practice under the supervision of
competent / experienced / qualified persons.
1.8.7) This information concerns the description of
the features, performances, assembly, disassembly,
maintenance, conservation, disinfection, etc. of the
device. Even if they contain some suggestions for
use, should not be considered an operating manual
in real situations (as well as a maintenance manual
of a car does not teach driving and does not replace
driving school).
2 - WORK AT HEIGHT
2.1) Additional information for individual fall protection
systems in the context of work at height.
2.2) For safety purposes, in these systems is essential to:
- carry out risk assessment and ensure that the entire
system, of which this device is only one part, is both
reliable and safe;
- prepare a rescue plan to deal with any emergencies
that could arise while using the device;
- position the anchor device or the anchor point as high
as possible;
- minimize the height of potential falls;
- use devices that are suitable for the purpose and
certified.
2.3) Important: in a fall arrest system the only device
that can be used it is a full body harness and this device
must comply with current regulations.
3 - STORAGE AND MAINTENANCE
3.1) Store the device in a dry place (relative humidity
40-90%), fresh (temperature 5-30 ° C) and dark,
chemically neutral (avoid absolutely saline and / or
acid environments), away from sharp edges, corrosive
substances or other possible prejudicial conditions.
3.2) Transport the device considering the precautions
foreseen for storage and limit direct exposure to sunlight
and moisture.
3.3) Maintain the device as follows:
- wash frequently with warm drinking water (30 ° C),
possibly with the addition of a neutral detergent;