INSTALLATION
Installation Explanations:
•∙Install∙the∙air∙conditioner∙on∙a∙flat∙surface∙at∙least∙12inches∙away∙from∙any∙wall∙or∙object∙that∙could∙block∙the∙airflow.(See∙Fig.7)
•∙Socket∙wiring∙should∙be∙in∙accordance∙with∙the∙local∙electric∙safety∙requirements.∙
Introduction to Exhaust Hose Installation
Temporary installation
•∙Twist∙both∙ends∙of∙the∙exhaust∙hose∙into∙the∙square∙fixing∙clip∙and∙the∙flat∙fixing∙clip.
•∙Insert∙the∙square∙fixing∙clip∙into∙openings∙at∙back∙of∙the∙air∙conditioner∙(see∙Fig.8).∙
•∙Put∙the∙other∙end∙of∙the∙exhaust∙hose∙to∙the∙near∙windowsill.∙
Window Slider Kit Installation
The∙window∙slider∙kit∙can∙be∙installed∙horizontally∙or∙vertically.∙Open∙the∙window∙and∙place∙
the window slider on the inside edge of the window. Adjust the window slider to the width of the
window.∙Fig.∙9∙and∙Fig.∙9a∙shows∙the∙minimum∙and∙maximum∙size∙windows∙for∙the∙window∙slider∙kit.
MAINTENANCE
Declaration:
•∙Before∙cleaning,∙be∙sure∙to∙disconnect∙the∙unit∙from∙any∙electric∙supply∙outlet;∙
•∙Do∙not∙use∙gasoline∙or∙other∙chemicals∙to∙clean∙the∙unit;∙
•∙Do∙not∙wash∙the∙unit∙directly∙(see∙Fig.10);∙
•∙If∙the∙conditioner∙is∙damaged,∙please∙contact∙the∙dealer∙or∙repair∙shop.
1.Air Filter
• If the air filter becomes clogged with dust/dirt, the air filter should be cleaned once every two weeks.
•∙ Dismounting
Open the air inlet grille and take off air filter.
•∙ Cleaning ∙∙∙∙∙Clean∙the∙air∙filter∙with∙neutral∙detergent∙in∙lukewarm∙water∙(104℉/40℃)∙and∙let∙it∙dry∙in∙the∙shade.
• Mounting
Put the air filter into the inlet grille, replace the components as they were.
2.Cleaning Air Conditioner Surface
First clean the surface with a neutral detergent and wet cloth, and then wipe it with a dry cloth.
Fig.7
Fig.9
window∙size
min: 2.75 ' ∙(84cm)
max:∙4.13 ' ∙(126cm)
9
ARP-7120/ARP-7120H
Fig.8
drain hose
Fig.9a
window∙size
min: 2.75 ' ∙(84cm)
max:∙4.13 ' ∙(126cm)
Fig.10