The conversion or adaptation to another type of gas must be carried out by a specialized technician. The nozzles for the
various types of gas are supplied in a packet and are marked in hundredths of mm (see table of "burners" technical
data).
•
Remove the control panel's front securing screws (see fig. G), remove the ignition cable from the piezoelectric
lighter (fig. D)
•
With a suitable spanner, unscrew the nozzle (fig. F pos 1) and put the appropriate one in its place (see the "Burner
technical data" table).
•
The main burner needs no adjustment for the primary air.
The flame of the pilot burner has fixed air.
The only job to do is change the nozzle (fig. E pos. 2) according to the type of gas.
In this case you have to unscrew the screws as specified above and, with an appropriate spanner, unscrew the fitting and
change the nozzle (fig. E pos. 2) with a suitable one. With the right nozzle, the flame should envelope the thermocouple
(fig. E pos. 3).
Important!
Once the appliance has been converted to work with a different type of gas, the technical specification plate has to be
updated, writing on it the type of gas the appliance has been converted to.
•
The appliance contains the instructions necessary for use.
•
Check the appliances for gas leaks.
•
Examine the flame of the pilot burner; it must lap the thermocouple and be blue, otherwise examine the nozzle of
the pilot burner.
•
Check the lighting and flame of the main burner.
•
We urge the user to follow the instructions when using the appliance.
With prolonged use of the appliance, it is indispensable to carry out regular maintenance for the safe functioning of the
appliance; we therefore recommend drawing up a contract for after sales service.
Maintenance must be done only by specialised personnel, observing the norms in force and our indications.
It is very easy to replace parts such as the valve, the piezoelectric lighter and the gas pipes.
To change such parts proceed as follows:
•
Cock (fig. C and fig. F): after having removed the front panel, unscrew the gas connection fittings and pull the
thermostat bulb out, then change the broken thermostat cock, putting the new one in its place.
•
To replace the thermocouple (fig. E pos. 3) unscrew the valve fitting and change the element.
•
The ignition plug (fig. E pos. 4) can be unscrewed and replaced.
Attention! In the event that smoke is given off, when the appliance is started up, it is necessary to let the installation
function without being used, for approximately an hour or until the smell disappears.
Brat Pans permit the cooking of many kinds of food. In fact they can be used for preparing sauces, soup, braised food,
stews, potatoes, etc.
Lighting the pilot burner
Push and turn the thermostat knob (01) into position
Keeping the knob pushed down, press the piezo button (03) repeatedly. The flame lights
automatically and can be seen trough the inspection hole in the front panel. After lighting, hold
the knob down for another 5-10 seconds, to allow the thermocouple to warm up, then release it.
The flame may go out, in which case it is necessary to repeat the procedure.
GB
REPLACING THE MAIN BURNER NOZZLE
REPLACING THE PILOT BURNER NOZZLE
CHECKING FUNCTIONING
MAINTENANCE
SPARE PARTS
INSTRUCTIONS FOR USE
LIGHTING THE MAIN BURNER
IE
29