3.4 Connecting sensors (PNP inputs)
For connecting sensors use cable type KM8−M8−GSGD−...
and plugs with union nut, M8x1 thread.
Fasten the plugs with the aid of the union nut in order to
prevent unintentional loosening, e.g. due to shock. Seal
unused sensor connections with the protective caps type
ISK−M8. Only in this way can you comply with protection
class IP65.
Please note
The inputs are resistant to short circuits. If a short cir
cuit occurs, the slave will be switched off. The AS−Inter
face master regards this slave as missing. When the
short circuit is eliminated, the slave registers immedi
ately as capable of functioning.
1
Inputs of the first
slave
2
Inputs of the second
slave
3
Pin assignment:
1: 24 V
3: 0 V
4: Input Ix