Maintenance
Inspect the Blender and its various parts and replace as follows:
Daily
Weekly
Quarterly

Troubleshooting

Problem
Blender fails to start,
or stops while it is
running and cannot
be restarted.
Blender fails to start or
stops while running,
and LED flashes when
paddle switch is
pressed.
Ingredients will not
mix properly.
6
Unplug the Blender and remove the Jar from the Blender Base, then inspect the
Jar and cutter assembly for wear, nicks, and broken or loose blades. Replace if
necessary. If the blades are loose, discontinue use immediately and replace the
blades.
Do not attempt to repair or tighten the cutter assembly. See "Technical Services."
Unplug the Blender, then inspect the power cord insulation and power plug for
cracks. Refer to "Technical Services" for repair or replacement.
Replace the Jar with cutter assembly as needed if inspection finds wear, nicks, or
broken or loose blades. See "Technical Services."
Solution
• Check to see if unit is securely plugged into an electric socket.
• Check to see if the integrated circuit breaker has tripped and reset it, if needed.
• Check to see if the fuse for the electric socket has blown or if a circuit breaker
has tripped.
• If the motor stops during operation due to overheating, unplug and allow the
unit to cool down for 15 minutes. Plug unit back in after 15 minutes to resume
normal operation.
• Check to see if Lid is placed in the correct orientation with the
Jar and ensure that the Lid is fully seated against the top of the
Jar.
• If the motor stops during operation due to the Lid rising,
push Lid down against the top of the Jar and restart blending
operation.
• Check to see if enough liquid has been added to the ingredients. Mixture should
be fluid and free-running at all times.
• Solid pieces are too large. Pieces should not exceed 1" cubes.
• Jar is too full. Do not fill past highest graduation marking.
• Cutter unit blades are not sharp or are damaged. Inspect Jar and cutter
assembly daily. Replace the Jar with cutter assembly as needed if inspection
finds wear, nicks, or broken or loose blades. See "Technical Services."
• Check to see if cutter assembly is installed properly.
• Select speed to create a fluid blend.