Lock Button; Emc Directive - Vimar Elvox 6209 Instrucciones Instalador

Portero automático petrarca due fili
Tabla de contenido

Publicidad

Intercommunicating call pushbutton programming
Programming phase:
1) Raise the handset of the interphone/video interphone to call (when using
series 8870, Giotto, Petrarca). With other versions of series 6600 (without
Petrarca
handset) press and keep pressed the talk/listen push-button
2) Remove the cover of the interphone to be programmed.
3) Press and hold the RESET push-button on the audio door entry unit to program.
4) Press and hold the additional pushbutton to make the intercommunicating call
together with the RESET pushbutton.
5) Release the RESET pushbutton, keeping the call pushbutton pressed.
6) After 2 seconds the interphone emits a high tone, while the other interphone
emits a 3-tone ascending scale.
7) Release the intercommunicating call pushbutton.
8) On the interphone called (with the 3-tone ring), press one of the programmed
pushbuttons (such as lock, F1, F2 or actuator).
9) A high tone confirms the end of the procedure.
Repeat the same procedure for the other interphones and any other intercommuni-
cating call pushbuttons.
Programming the self-start pushbutton to a specific panel.
Programming phase:
1) Remove the interphone cover.
2) Press and hold the RESET pushbutton on the interphone.
3) Press and hold the additional pushbutton to activate the self-start function to-
gether with the RESET pushbutton.
4) Release the RESET pushbutton, keeping the self-start pushbutton pressed.
5) After 2 seconds the interphone emits a high tone.
6) Release the self-start pushbutton.
7) On pushbutton entrance panels, press the call button for the interphone, while on
alphanumeric keypads, enter the call code and press pushbutton "
8) A high tone confirms the end of the procedure.
Restoring default values of pushbuttons (P2,P3,P4,P5,P6,P7,P8)
Programming phase:
1) Remove the interphone cover.
2) Press and hold the RESET pushbutton on the interphone.
3) Press and hold the relative pushbutton to be reprogrammed together with the
RESET pushbutton.
4) Release the RESET pushbutton, keeping the other pushbutton pressed.
5) After 2 seconds the interphone emits a high tone.
6) Release the pushbutton to restore to default and then press again.
Deleting all settings.
Programming phase:
This procedure is advised when you want to change the ID of an interphone/monitor
previously programmed and you do not want keep the operation programming of
the appliance.
1)
Remove the interphone cover.
2) Press and hold the RESET pushbutton on the interphone.
3) Press and hold the self start pushbutton together with the RESET pushbutton.
4) Release the RESET pushbutton, keeping the self-start pushbutton pressed.
5) After 2 seconds the interphone emits a continuous tone for two seconds.
6) Release the self-start pushbutton.
7) During the continuous tone, press the tab on the lock release pushbutton.
If the deletion procedure is successful, when the lock release tab is pressed once
more the interphone emits a triple "Beep".
OPERATION
Calls from an entrance panel, intercommunicating calls and door calls are differenti-
ated by means of different tones.
Door calls.
Calls from entrance panels do not follow the pressed pushbutton but are generated
inside the interphone. The call interval is 1 s of ringtone and 2 s of pause repeated
twice (default value set on panel). To answer, raise the handset. If the handset is
already raised during the call, replace and raise it again. The call answer time (30
s) and the conversation time (2 minutes by default) are set in the panel parameters.
When the conversation time has elapsed, the user can continue without replacing
the handset if a new call is made within 10 s from the same panel.
Intercommunicating call.
Lift the handset and press the intercommunicating button for the interphone/monitor
to be called. On the handset of the interphone called a call tone will ring (if the call is
enabled) or an engaged tone (if not enabled). On the called interphone the ringtone
starts sequentially at intervals of 1 s ringing and 4 s pause. The maximum duration of
the call is 30 s (6 cycles). To answer the call, simply raise the handset; the maximum
6
duration of the conversation is 60 seconds. When the conversation time has elapsed,
the user can continue without replacing the handset if a new call is made within 10 s.
Calls from the panel have priority over intercommunicating calls.
Denied calls.
.
Installation of type 6153/682 in the interphone, enables the user to vary the call
intensity or mute the ringtone. Call mute is indicated by permanent illumination of
the red LED. If calls are made to the interphone when the call mute is enabled, they
are denied. A denied call causes the red Led to briefly switch off according to the
number of times calls are denied (maximum 4 denied calls). The signal is repeated
every 10 s (approx.). Deletion of denied calls is by: reenabling the ringtone, resetting
the interphone or a system power failure. On the panel, a denied call is indicated by
means of a dissuasion tone (a series of "Beeps" at 100ms intervals with a pause of
100ms for a total of 5 s).
The message "Do not disturb" also appears on panels with display.

Lock Button

The lock button of each device works in the following manner.
- Device with handset at rest
spoken or from which it has been called.
- Device with handset raised but not engaged in a conversation
board if the Switchboard flag is YES. Otherwise it goes back to the first case.
- Device with handset raised and engaged in an internal conversation
the first case.
- Device with handset raised and engaged in an external conversation or called
from entrance panel lock
which it has been called.
In practice a lock is always activated except when the handset is raised and you
immediately press the lock button. This can also be taken to the standard case if the
system has no porter switchboard and the Switchboard flag is set on NO.
".
INSTALLATION RULES.
Installation should be carried out observing current installation regulations for elec-
trical systems in the Country where the products are installed.
CONFORMITY.

EMC directive

Standards EN 60065, EN 61000-6-1 and EN 61000-6-3.
INFORMATION FOR USERS UNDER DIRECTIVE 2012/19/UE (WEEE)
In order to avoid damage to the environment and human health as well
as any administrative sanctions, any appliance marked with this symbol
must be disposed of separately from municipal waste, that is it must be
reconsigned to the dealer upon purchase of a new one. Appliances marked
with the crossed out wheelie bin symbol must be collected in accordance with the
instructions issued by the local authorities responsible for waste disposal.
lock to the last entrance panel with which it has
to the entrance panel being spoken with or from
call to switch-
as in
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido