PR electronics PRetrans 5335 Manual Del Usuario página 20

Transmisor de 2 hilos con protocollo hart
Ocultar thumbs Ver también para PRetrans 5335:
Tabla de contenido

Publicidad

LERBAKKEN 10, 8410 RØNDE DENMARK.
For safe installation of 5335D, 5336D or 5337D the following must be observed. The module shall
only be Installed by qualified personnel who are familiar with the national and international laws,
directives and standards that apply to this area.
Year of manufacture can be taken from the first two digits in the serial number.
IECEx Certificate
Marking
Standards
Hazardous area
Zone 0, 1, 2, 20, 21, 22 and Coal mining
T4: -40 ≤ Ta ≤ 85ºC
T6: -40 ≤ Ta ≤ 45ºC
Terminal: 3,4,5,6
Uo: 9.6 VDC
Io: 28 mA
Po: 67 mW
Lo: 35 mH
Co: 3.5μF
Revision date:
2014-03-31
18
IECEx Installation drawing
IECEx KEM.10.0083X
Ex ia IIC T6..T4 Ga
Ex ia IIIC Da
Ex ia I Ma
IEC60079-11:2006, IEC60079-0: 2007
IEC60079-26:2006, IEC61241-11:2005
6
5
4
5335D
3
5336D
5337D
Terminal: 1,2
Ui: 30 VDC
Ii: 120 mA
Pi: 0.84 W
Li: 10μH
Ci: 1.0nF
Version Revision
V4R0
5335V115-ES
WWW.PRELECTRONICS.COM
Non Hazardous Area
+
1
-
2
Barrier
5335QE01
Page: