Please read Troubleshooting Guide and/or visit
www.insinkerator.com before calling AnswerLine
PROBLEM
Water and steam spits
forcefully from spout
without turning on the
dispenser faucet.
Water is not hot
Water is too hot
or not hot enough
Water is dripping from
the spout/vent
intermittently
Water is dripping
from the spout/vent
constantly
Divided stream
If you are still experiencing trouble call the AnswerLine
12
TROUBLESHOOTING
POSSIBLE CAUSE
• Unit is boiling.
May be normal during initial setup.
• The unit is unplugged.
• The electric outlet is inoperative.
• Thermostat is not adjusted to
your needs.
• The expansion chamber isn't draining
properly due to low water pressure.
• The spout is blocked.
• Debris in the water line may be
in the faucet valve seat causing a
slow water leak.
• Debris in the end piece.
WHAT TO DO
• Depress faucet lever to release some water from
the tank.
• Adjust water temperature using dial on tank front.
Remember that at higher altitudes, water boils
at lower temperatures.
• Make sure the unit is connected to a properly grounded
electric outlet.
• Make sure the circuit breaker fuse is functioning properly.
• Check that the outlet is not switched off.
• Adjust the thermostat slowly, then depress or twist faucet handle
for 20 seconds to bring in fresh water to be heated at the new
setting. Allow 5-7 minutes for water to reach new temperature.
• Unplug the unit. If the dripping doesn't stop after a few
minutes, check the supply valve to ensure that is fully
open and there are no obstructions in the water line
reducing the pressure below 30 psi ( i.e., a poorly mounted
saddle valve, a clogged water filter, or a partially opened
shut-off valve).
• Unscrew spout end piece and clean out any debris.
• Unscrew spout end piece and clean out any debris.
• Depress lever 7-10 times to flush faucet & lines.
• Unscrew spout end piece and clean out any debris.
™