The inflowing water quantity has to be adjusted in a way that approx. 1 – 3 l/h flow through the 6
mm pipe into the reactor. The adjustment and the quantity of CO
depends on the aquarium size
2
and the calcium requirements of the animals.
5. Starting
The Calcium reactor has to be closed by eight clamps that are pushed on from the side. Before
starting the unit, please check that the sealing is inserted correctly and all clamps are tightened.
As soon as the Calcium reactor is placed in the right position and all connections are ready, the
water flow can be started. Then, the reactor is filled up with water until water comes out of the
outlet. Afterwards, the CO
can be switched on. The quantity of CO
has to be adjusted the way
2
2
that the pH-value in the aquarium does not drop below pH 7.8. Within the reactor itself, the pH-
value should drop to pH 5.9 - 6.0. It is possible to control the pH-value in the reactor by e. g. the
Aqua Medic pH-Controller or the pH Computer. In the top, there is a hole to srew in a pH
electrode.
The back flow of the calciumbicarbonate enriched water either into the aquarium or filter tank
should be directed to a well-flushed place in order to mix it immediately with aquarium water. This
avoids instabilities of the pH-value.
6. Maintenance
The Aqua Medic Hydrocarbonate is consumed by the chemical reaction and has to be refilled from
time to time. Every 1 - 2 years, it should be replaced completely. Also the flow rate should be
checked regularly.
7. Warranty
Should any defect in material or workmanship be found within 12 months of the date of purchase
AB Aqua Medic GmbH undertakes to repair or, at our option, replace the defective part free of
charge – always provided the product has been installed correctly, is used for the purpose that was
intended by us, is used in accordance with the operating instructions and is returned to us carriage
paid. The warranty term is not applicable on the all consumable products.
Proof of Purchase is required by presentation of an original invoice or receipt indicating the dealer's
name, the model number and date of purchase, or a Guarantee Card if appropriate. This warranty
may not apply if any model or production number has been altered, deleted or removed,
unauthorised persons or organisations have executed repairs, modifications or alterations, or
damage is caused by accident, misuse or neglect.
We regret we are unable to accept any liability for any consequential loss.
Please note that the product is not defective under the terms of this warranty where the product,
or any of its component parts, was not originally designed and / or manufactured for the market in
which it is used.
These statements do not affect your statutory rights as a customer.
If your AB Aqua Medic GmbH product does not appear to be working correctly or appears to be
defective please contact your dealer in the first instance.
Before calling your dealer please ensure you have read and understood the operating instructions.
If you have any questions your dealer cannot answer please contact us.
Our policy is one of continual technical improvement and we reserve the right to modify and adjust
the specification of our products without prior notification.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
- Technical changes reserved – 02/2015