ELECTRIC START WIRING

The generator is equipped with electric start. An "Off-On-
Start" rotary key switch is provided on the recoil end panel. All
necessary wiring is provided. The battery is customer provided.
See engine manual for wiring diagram (3A Charge Coil), and
additional information.
DC FEATURES
The charging system of the unit is supplied by the
starter/alternator of the engine. 12 volts DC is constantly
charging the battery when the unit is running . Disconnecting
the battery will stop the charging of the battery.
Before charging a storage battery, check the electrolyte
fluid level in all the cells. (Sealed batteries do not require
checking). Add distilled water to each cell if necessary, to
bring the level back up to the manufacturer's required level.
WARNING: Storage batteries give off
EXPLOSIVE hydrogen gas while charging. Do
not allow smoking, open flames, sparks, or
spark producing equipment in the area while
charging.
WARNING: Battery electrolyte fluid is
comprised of sulfuric acid that can be very
dangerous and cause severe burns. Do not
allow this fluid to contact eyes, skin, clothing,
etc. If contact or spillage does occur, flush
the area with water immediately.
CAUTION: This battery charging system is
intended to recharge weak batteries, not to
"boost start" vehicles. Do not overcharge
battery or leave battery unattended.
CAUTION: Do not continue to charge a
battery that becomes hot or is fully charged.

BATTERY INSTALLATION

Koshin America recommends a 12 V battery with at least
235 cranking amps, Model U1L, Lawn and Garden Battery.
1. Remove battery heat shield by loosening the four M6
screws (item F).
2. Place the battery in the position provided.
3. Place the bolts through the holes on the battery pan.
4. Place the bolts through the loops on the Hold-Down
bracket.
5. Place the spacers and washers on the bolts.
6. Tighten down the Hold-Down assembly with the 1/4-20
nuts provided.
7. Reinstall battery heat shield.
Note: Spacers may be removed depending on the battery
height.
4
BATTERY HEAT SHIELD:
Inspect to ensure that all heat shields and heat deflectors
are intact and in place. Removing or modifying parts could
cause serious damage to the battery.
WARNING: Batteries contain sulfuric
acid (when filled). May contain explosive
gasses. Always abide by safety warnings
provided with the battery.
-
Keep sparks, flame and cigarettes away.
-
Hydrogen gas is generated during
charging and discharging.
-
Always shield eyes, protect skin and
clothing when working near batteries.
Connect the red 8 ga. battery lead to the positive (+)
battery post and the black 8 ga. battery to the negative (-)
battery post with the bolts and nuts provided.

BATTERY KIT PARTS LIST

Item
Description
A.
*Bolt, 1/4-20 X 8"
B.
*Washer 1/4
C.
*Spacer
D.
Hold Down bar (P/N 0036525.02)
E.
*Nyloc nut, 1/4-20
* These are standard parts available at your local hardware
store.
Qty.
2
2
2
1
2