WIND sensor
4.1
1.1
The anemometer (ANEM4) detects wind speed, which the control unit compares with the threshold set through DIPs 1-2-3 (see table).
The control unit is only compatible with anemometers generating 4 pulses per rev.
ALARM ACTIVATED when
The detected speed is higher than
the set threshold (see table at side).
TEMPERATURE sensor
4.2
1.1
The temperature sensor (NTC 10K/3435K) activates whenever there is danger of ice forming.
ALARM ACTIVATED when
The measured temperature is below 2 °C.
Activation/deactivation of the TEMPERATURE sensor by means of P1 *
**
7x
P1
Activation/deactivation of the TEMPERATURE sensor by means of the transmitter *
Activation (only if the sensor is connected)
Press the "STOP" button of a memorized 7/42
or 3-channel transmitter 10 times and hold the
last time for 2 s. The buzzer emits a continuous
sound for 4 seconds.
* The motors must be stopped. ** The buzzer will make a beep each time the button is pressed.
Alarm priority
HIGH
What happens with ALARM ACTIVATED
The control unit tilts the pergola slats at 33% of full
opening. The control unit executes no command.
Alarm priority
MEDIUM
What happens with ALARM ACTIVATED
The control unit tilts the pergola slats to 66% of full opening. The
control unit only executes hold-to-run commands.
(
5 s)
STOP
***
continuous
(10x)
sound 4 s
L4
ALARM NOT ACTIVE when
The sensor has detected a lower speed
than the set threshold for 60 seconds.
L4
continuous
sound
4 s
L4 flashes
once every 3 s
Deactivation
Press the "STOP" button of a memorized 7/42
or 3-channel transmitter 10 times and hold the
last time for 2 s. The buzzer emits 2 beeps.
L4 flashes once every 3 seconds.
*** The motors make short movements
11
Factory setting
ACTIVATED
DIP1
DIP2
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
Factory setting
DEACTIVATED
ALARM NOT ACTIVE when
The measured temperature is above 3 °C.
ACTIVATION ***
(only if the sensor is connected)
DEACTIVATION ***
STOP
(10x)
DIP3
Km/h
OFF
40
ON
45
OFF
50
ON
55
OFF
60
ON
65
OFF
70
ON
75