5. Preparing the plasma display
Attaching the insulation spacers
Place the front surface of the plasma display on a clean
cloth that has no dirt or foreign objects on it, and follow the
procedure below.
If the plasma display has any protruding parts, take care not to
scratch or damage them.
Remove the four caps from the plasma display using a Phillips
head screwdriver.
Note
• Keep the caps that were removed in a safe place.
(They will be required if you use the pedestal.)
Using the supplied Allen wrench
head countersunk screws
4 insulation spacers
removed as shown in the figure on the right.
(Tightening torque: 3 to 4 N•m)
Connect the power cord and the cables for connecting other
units.
Notes
• For details on wiring, see the instruction manual of the plasma
display.
• When attaching the plasma display to the wall-hanging bracket, take
care that the power cord and the cables for connecting other units
are not caught between the plasma display and the wall or bracket.
6. Attaching and securing the plasma display to the wall-hanging bracket
• When installing, make sure that the power cord and the cables for
connecting other units are not caught between the plasma display
and the wall or bracket.
Horizontal installation
Engage the upper insulation spacers of the plasma display
with the cutouts at the top of the bracket unit, and slowly lower
them into place.
While lifting the plasma display slightly, insert the bottom
insulation spacers into the holes at the lower end of the wall-
hanging bracket, and then pull the plasma display straight
down into place.
Vertical installation
Rotate it clockwise 90 degrees so that the Panasonic logo is on
the left side, and then attach it using the same procedure as for
horizontal installation.
CAUTION
• If the plasma display is lifted too much, its top part will become
disengaged from the wall-hanging bracket.
, mount the supplied 4 Allen
, 4 dished toothed washers
at the locations where the caps were
Phillips head screwdriver
Blanket
and
Blanket
Upper insulation
spacer
Horizontal installation Vertical installation
Cutout at top
Cap
Hole at
bottom
Lower
insulation