Take out packaging and clean all the cabinet using warm water together with 5% of neutral soap then
dry it with a soft-cloth; for the glass parts only use specific products, avoiding the use of water which
can leave on the glasses limestone residues.
The refrigerator must be moved only using a service-lift; during all operations the refrigerator must be
peremptory positioned on the suitable pallet supplied.
Place the counter in horizontal position on a clean surface,
away from sources of heat (radiators, ovens, etc) icluded sun
rays and away from draughts (for example fans, air condi-
tioning ducts).
In fact anything that causes the temperature to the inside of
the cabinet to rise with detrimental results to the operation of
the unit and energy consumption.
Do not install the unit in open places and do not expose it
to rain.
It is necessary taht the condensing unit obtains a good circu-
lation of air around it.
Also the area around the condensing unit should not be ob-
structed by boxes or other objects; keep a distance from the
wall of 10 cm. at least.
Never use electrical equipment in the refrigerated compartment.
Never place containers of liquid on or immediately above the ticket counter; should the content
spill out, it would damage the counter.
Install and position the unit in such a way so as to allow easy access to the power socket.
THE REFRIGERATOR IS NOT SUITABLE FOR WORKING IN DANGEROUS ENVI-
RONMENT WITH RISK OF FIRE, EXPLOSIONS OR RADIATION.
Operation is regular with ambient temperature indicated on technical data plate.
INFORMATIONS ABOUT USE

PUTTING INTO OPERATION

Check that the voltage on the identification plate is the same
as that of the network.
THE ELECTRICAL SUPPLY LINE TO WHICH THE
REFRIGERATOR WILL HAVE TO BE CONNECTED IS
TO BE PROTECTED BY A VERY SENSITIVE DIFFE-
RENTIAL SWITCH (Rc=16A,Dc=30mA); IT IS ALSO TO
BE LINKED TO THE GENERAL EARTHING PLANT.
Earthing is necessary and compulsory by law.
Absolutely never use reduction units, patch cords, adapters
or multiple socket outlets to connect the counter.
DIRECTLY connect the equipment to the mains.
The manufacturer disclaims all responsability for any damage
to people or things due to incorrect observance of this rule.