INSTAL L T HE
RECIRCU LATION BOX
1. Cut opening in cabinet base.
• Size: 14 1/2" (368) x 15" (380)
• Orientation depends upon direction of exhaust.
• Double-check that blower outlet and recirculation box inlet will align.
2. Temporarily place recirculation box into opening in cabinet base.
• Rotate back of box up slightly and insert exhaust end down into opening.
• Mark location of exhaust opening in toe space, rear, or side of cabinet.
3. Remove recirculation box from opening.
4. Cut exhaust opening.
• Size: 3 1/2" (89) x 14 1/4" (362)
• This opening will be covered with decorative grille.
5. Replace recirculation box into opening in cabinet base.
• If necessary, attach a length 3 1/4" (83) x 14" (356) duct extension (not
included) to extend from recirculation box outlet to decorative grille
location.
• Seal the duct connection(s) with aluminum tape to make them secure
and air tight. Do not use duct tape.
• Use 6 - #10 x .625" screws to secure recirculation box to cabinet base.
6. Install blower.
• See blower instructions.
• Use 8" (203) round duct to connect blower exhaust to recirculation box
inlet
• Seal the duct connections with aluminum tape to make them secure
and air tight. Do not use duct tape.
• Drill 1/8" (3) pilot holes through top of recirculation box and attach legs to
recirculation box with 4 - #8 x .375" screws.
7. Install decorative grille.
• Use screws provided.
8. Remove polyfilm from filter.
• Lift filter from slot.
• Remove polyfilm.
• Replace filter into slot.
Blower mounted
to downdraft using
mounting legs.
BLOWER
ALIGN BLOWER
OUTLET WITH
RECIRCULATION
BOX INLET
EXHAUST THROUGH
CABINET FRONT (TOE SPACE)
FILTER RE PLACEM ENT
It is recommended that you replace the recirculation filter every
6 months. However, this may vary, depending upon the type
and amount of cooking you do. Call customer service or your
local distributor to order filter replacement Model HDDFILTUC.
5
OPTIONAL REMOTE BLOWER MOUNT
Blower mounted to
framing in remote
location - using
mounting brackets.
Blower outlet and
BLOWER
recirculation box
inlet must align.
(See below.)
METAL 8" ROUND
DUCT (per local codes)
MOUNTING
LEGS
EXHAUST THROUGH
14 1/2"
(368)
Measurements
in inches
(mm).
DECORATIVE
GRILLE
4 1/2"
(114)
Measurements
in inches
(mm).
CABINET SIDE
CUSTOM-M ADE
DECORAT IV E GRIL LE
You can make your own decorative grille. Use the decorative
grille in this kit as a template for the overall size and mounting
hole locations. The grille opening pattern is up to you.
Equivalent area of grille slots for proper air flow = 18 in.
15"
3 1/2" (89) x 14 1/4" (362)
(380)
EXHAUST OPENING
3 1/2" (89) x 14 1/4" (362)
EXHAUST OPENING
16"
(406)
16"
(406)
8"
(203)
6 1/2"
(165)
(356)
12 1/4"
(311)
EXHAUST THROUGH
CABINET BACK
EXHAUST
THROUGH
CABINET
SIDE
DECORATIVE
GRILLE
EXHAUST
THROUGH
CABINET
BACK
14 1/2"
(368)
15"
(380)
DIMENSIONS
17 1/2"
(445)
3 1/4"
(83)
3 3/4"
(95)
14"
15"
(380)
16"
(406)
min.
2