Para comprobar la temperatura interna

Para comprobar la temperatura interna del servidor, así como los límites de
temperatura para el envío de advertencias o el cierre del servidor, escriba:
# lom -t
Por ejemplo:
EJEMPLO DE CÓDIGO 3-6
# lom -t
System Temperature Sensors:
1 SSC1
t_sbbc0
2 SSC1
t_cbh0
3 SSC1
t_ambient0
4 SSC1
t_ambient1
5 SSC1
t_ambient2
6 RP0
t_ambient0
7 RP0
t_ambient1
8 RP0
t_sdc0
9 RP0
t_ar0
10 RP0
t_dx0
11 RP0
t_dx1
12 RP2
t_ambient0
13 RP2
t_ambient1
14 RP2
t_sdc0
15 RP2
t_ar0
16 RP2
t_dx0
17 RP2
t_dx1
18 SB0
t_sdc0
19 SB0
t_ar0
20 SB0
t_dx0
21 SB0
t_dx1
22 SB0
t_dx2
23 SB0
t_dx3
24 SB0
t_sbbc0
25 SB0
t_sbbc1
26 SB0/P0
Ambient
27 SB0/P0
Die
28 SB0/P1
Ambient
29 SB0/P1
Die
30 SB0/P2
Ambient
31 SB0/P2
Die
32 SB0/P3
Ambient
33 SB0/P3
Die
34 SB2
t_sdc0
Ejemplo de resultados obtenidos con el comando lom -t
36 degC : warning 102 degC : shutdown 107 degC
45 degC : warning 102 degC : shutdown 107 degC
23 degC : warning 82 degC : shutdown 87 degC
21 degC : warning 82 degC : shutdown 87 degC
28 degC : warning 82 degC : shutdown 87 degC
22 degC : warning 82 degC : shutdown 87 degC
22 degC : warning 53 degC : shutdown 63 degC
62 degC : warning 102 degC : shutdown 107 degC
47 degC : warning 102 degC : shutdown 107 degC
62 degC : warning 102 degC : shutdown 107 degC
65 degC : warning 102 degC : shutdown 107 degC
23 degC : warning 82 degC : shutdown 87 degC
22 degC : warning 53 degC : shutdown 63 degC
57 degC : warning 102 degC : shutdown 107 degC
42 degC : warning 102 degC : shutdown 107 degC
53 degC : warning 102 degC : shutdown 107 degC
56 degC : warning 102 degC : shutdown 107 degC
48 degC : warning 102 degC : shutdown 107 degC
39 degC : warning 102 degC : shutdown 107 degC
49 degC : warning 102 degC : shutdown 107 degC
54 degC : warning 102 degC : shutdown 107 degC
57 degC : warning 102 degC : shutdown 107 degC
53 degC : warning 102 degC : shutdown 107 degC
53 degC : warning 102 degC : shutdown 107 degC
40 degC : warning 102 degC : shutdown 107 degC
29 degC : warning 82 degC : shutdown 87 degC
57 degC : warning 92 degC : shutdown 97 degC
27 degC : warning 82 degC : shutdown 87 degC
51 degC : warning 92 degC : shutdown 97 degC
27 degC : warning 82 degC : shutdown 87 degC
53 degC : warning 92 degC : shutdown 97 degC
29 degC : warning 82 degC : shutdown 87 degC
50 degC : warning 92 degC : shutdown 97 degC
51 degC : warning 102 degC : shutdown 107 degC
Capítulo 3 Lights Out Management