Technical Specifications; Troubleshooting - STEINEL PROFESSIONAL IR 180 DALI Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
Making Claims
If you wish to make a claim, please send your product complete and carriage
paid with the original receipt of purchase, which must show the date of
purchase and product designation, either to your retailer or contact us at
STEINEL (UK) Limited, 25 Manasty Road, Axis Park, Orton Southgate,
Peterborough, PE2 6UP, for a returns number. For this reason, we recom-
mend that you keep your receipt of purchase in a safe place until the warranty
period expires. STEINEL shall assume no liability for the costs or risks involved
in returning a product.
G B
For information on making claims under the terms of the warranty, please go to
www�steinel-professional�de/garantie
1
If you have a warranty claim or would like to ask any question
Y E A R
regarding your product, you are welcome to call us at any
time on our Service Hotline
MANUFACTURER'S
WARRANTY
01733 366700.
11� Technical specifications
Dimensions W × H × D
Supply voltage
Sensor system
Sensor system
Angle of coverage
Light-level setting
Time setting
Mounting height
Controllable DALI electronic ballasts
DALI output 1 / output 2
Twilight setting
IP rating
Temperature range
* At extreme angles, the reach of the HF 180 is extensively determined by local
conditions.
5
3
Y E A R
Y E A R
MANUFACTURER'S
MANUFACTURER'S
WARRANTY
WARRANTY
80 × 80 × 50 mm
220-240 ~V / 50/60 HZ
Passive infrared (IR) / high-frequency (HF)
IR max. 20 m (tangential) /
max. 4 m (radial) / HF max. 8 m
180°
*
10-1000 lux, ∞ / daylight
30 sec - 30 min,
Time setting, IQ mode (automatic
adjustment to the usage profile)
1.1 m
12 DALI electronic ballasts per output
2-core DALI control cable / broadcast
2 - 1000 lux
IP20
0°C to 40°C
- 30 -
12� Troubleshooting
Malfunction
Cause
Light does not switch ON n No supply voltage
n Lux setting too low
n No motion being
detected
Light does not switch OFF n Lux setting too high
n Stay-ON time still
effective
n Interfering heat sources:
e.g. fan heater, open
doors and windows,
pets, light bulb / halo-
gen floodlight, moving
objects
Sensor switches OFF
n Stay-ON time too short
despite persons being
n Lux setting too low
present
Sensor does not switch
n Stay-ON time too long
OFF quickly enough
Sensor does not switch
n Reach is reduced when
ON quickly enough when
approached from the
approached from the front
front
Sensor does not switch
n Lux setting too low
ON when persons are
present despite it being
dark
Switch not working
n Switch deactivated?
Remedy
n Check supply voltage
n Slowly increase lux set-
ting until light switches
ON
n Ensure unobstructed
sensor vision
n Check detection zone
n Reduce lux setting
n Wait until stay-ON time
elapses; reduce stay-
ON time if necessary
n Use stickers to mask
out stationary sources
of interference
n Increase stay-ON time
n Change lux setting
n Reduce stay-ON time
n Install additional sensors
n Reduce distance
between two sensors
n Sensor deactivated by
switch?
n Semi-automatic mode?
n Increase lux setting
n Check DIP switch 3
setting