Checklist:
No.
Range
General
1
inspection
Inspecting
2
the glass
Gas control
3
system inspection
The combu-
4
stion chamber
inspection
The control
5
device inspection
46
Carry out the firing procedure in the heater.
Verify the correct operation of all the safety systems.
Make sure the main burner flame is stable. Make sure the main
burner is burning evenly.
Make sure the batteries in the receiver and in the remote control do
not need to be replaced (automatic gas control system only)
Verify that all modes in the remote control are working correctly
(automatic gas control system only)
Make sure the glass does not have cracks.
Check the degree of dirt on the glass. If necessary, clean the glass.
Check the tightness of the gas connections.
Check that the cylinder compartment ventilation is not blocked.
Check the wires connecting the controller to the receiver for damage.
Check if the gas control system components are not exposed to high
temperatures.
Make sure that the inner compartment and its components are
not exposed to moisture. Check the connecting wires for signs of
corrosion.
Make sure that the control burner is not blocked by ornamental
elements.
Make sure that the thermocouple is within the control flame range.
Make sure the combustion chamber does not require cleaning.
Make sure that all the air supply holes in the combustion chamber
are clear. If necessary, unblock the holes.
Check the combustion chamber for signs of corrosion. If necessary,
remove the corrosion and cover the losses with a new layer of paint.
Make sure the main burner ignites smoothly.
Make sure the receiver antenna is not damaged (automatic gas
control system only).
Check for punctures in the circuits (automatic gas control system
only).
Activities