START-UP PROCEDURE

PRE-START PREPARATION
Before starting the pressure washer, check for loose or
missing parts and for any damage which may have occurred
during shipment.
START-UP PROCEDURE
1. Make sure water supply is connected and turned on.
2. Release gun safety if locked.
3. To allow air to escape from the hose, squeeze trigger on
the gun until there is a steady stream of water coming
from the nozzle.
4. Remove any dirt or foreign matter from the gun outlet and
the male connector of the wand.
5. Insert the nozzle wand into the gun wand and tighten the
fitting securely.
6. Place the throttle in the HI position.
STARTING THE ENGINE
1. Check oil and fuel level.
2. Adjust choke prime as necessary.
3. Set the engine switch to the "ON" position.
4. Squeeze trigger on pressure washer to release pressure
while pulling on the engine starter rope with a fast steady
pull. Pressure may otherwise build up making starting the
unit difficult.
5. As the engine warms up, readjust the choke.

SPRAY NOZZLE SELECTION

Following is information concerning the three nozzles
provided with your pressure washer.
NOTE: The force of the spray on the surface you are
cleaning increases as you move closer to the surface.
0° High Pressure (Red): The water stream discharged is
very aggressive. Use with extreme caution to prevent damage
to the surface being cleaned or injury to persons or animals.
15° High Pressure (Yellow): This is the nozzle used for
most cleaning applications. It provides wide coverage and a
powerful water stream.
40° High Pressure (White): This nozzle is used for
cleaning with a wider coverage over a larger area with a
powerful water stream.
65° Low Pressure (Black): Provides los pressure spray
and a wide coverage. Used primarily when operating the
chemical injector to apply chemicals.
HIGH PRESSURE HOSE
Attach the high pressure hose to the fitting located on the
front side of the side panel. Only Coleman Powermate
Pressure Washer high pressure hoses should be used.
WATER CONNECTION
Before connecting the inlet hose to the unit, run water
through the garden hose (not supplied) to flush out any foreign
matter. Connect the inlet hose to the appropriate fitting
located on the back side of the panel.
GXR2525 SERIES TORQUE SPECIFICATIONS
Item
10
40
Oil Seal Kit (9468)
Order # 0057960
Plunger Packing Kit (9465)
Order # 0057958
Valve Assembly Kit (9466)
Order # 0057959
Unloader Repair Kit (9467)
Order # 0058691
Maximum Inlet Pressure . . . . . . . . . . . . . . . . .Up to 90 PSIG
RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3600 RPM
Temperature of Pumped Fluids . . . . . . . . . . . . . . .Up to 80°F
Inlet Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(2) 1/2" BSP
Discharge Ports . . . . . . . . . . . . . . . . . . . . . . . . .(2) 3/8" BSP
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 lbs.
Crankcase oil Capacity . . . . . . . . . . . . . . . . . . . . . .4.7 fl. oz.
Pump oil . . . . . . . . . . . . . . . . . . . . . .SAE 30W Nondetergent
Consult the factor for special requirements that must be met if
the pump is to operate beyond one or more of the limits
specified above.

OPERATING CONNECTIONS

5
Description
Torque Amount
Socket Bolt
100 in.-lbs.
Stud Bolt 150 in.-lbs.
GXR2525 SERIES REPAIR KITS
GXR2525 SPECIFICATIONS
INLET HOSE
HIGH PRESSURE HOSE