Changing Back Tamper Position; Back Tamper Terminal Wiring; Dip Switch Settings - Risco WatchOut Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Changing Back Tamper position

The back tamper is by default secured on the right
side of the internal base (Rear view). If you wish to
move it to the left side (rear view), do the following
(Figure 5):
1. Remove tamper screw 1 in order to release the
tamper from position 7.
2. Ensure tamper spring (2) rests over tamper wire
base 4.
3. Ensure plastic tamper bracket (3) rests over
both 2 and 4.
4. Secure tamper screw (1) into (3) over position 6.
Notes:
1.
Verify that you hear a "Click" when attaching the tamper spring to the wall.
2.
For pole installation, the tamper can be moved to the bottom right-hand side of the internal base.

Back Tamper Terminal Wiring

If you wish to use the back tamper (recommended) remove the short from the back tamper terminal
block and connect the back tamper wires to the back tamper terminal block.

DIP Switch Settings

ON
Factory
Default
1
2
3
4
5
6
DIP 1: LEDs operation
On: LEDs enabled
Off: LEDs disabled
DIP 2-3: PIR Detection Sensitivity
Sensitivity
DIP2
DIP3
Low
Off
Off
Mid
Off
On
Normal
On
Off
Maximum
On
On
Figure 5
1
2
BACK TAMPER
Back Tamper in use
Back Tamper not used
H1
H1
Short
DIP 4: Supervision time
On: 65 minutes
Off: 15 minutes
DIP 5: Normal/Test modes
On: Test
Off: Normal
DIP 6: Anti masking operation
On: Enabled
Off: Disabled
Installation Instructions
Left Side
Tamper
6
Right Side
Tamper
7
3
5
4
Figure 5