MASTER PROGRAMMING MODE
2510SE, 2750SE, 2850SE, 2900SE, 2910SE, 4600SE, 5000SE,
5600SE, 8500SE, 9000SE, 9100SE AND 9500SE
1. 1 Push this button
once per display.
2. Use these buttons
set the programming.
Note: For 8500SE, 9000SE,
9100SE and 9500SE, set 7--2
Si 7- - 1 is programmed,
this display will not be viewed
Si 7- - 2 is programmed,
this display will not be viewed
Si 7- - 1 is programmed,
imperatively set a number of day
To set the cycle time,
see the next page.
Si 7- - 1 is programmed,
this display will not be viewed
11.a Valve type
o--1
o--1 2510SE, 2750SE
2850SE, 2900SE,
2910SE, 4600SE,
5000SE and
5600 SE valves
With the display set to 12:01. PM, push and hold these
12:01
buttons
for 5 seconds.
1. Display format: litre or cubic meter
U--2
U--1
Gallon (g) - not used
U--2
Litre (l)
U--4
Cubic meter (m
2. Regeneration type
7--2
7--1
Timeclock regeneration
7--2
Meter immediate
7--3
Meter delayed
3. Treated water capacity
in Litre or Meter cube following the choice of unit
2800
Ex: 2800
4. Regeneration time
2:00
Ex: 2:00
5. Regeneration day override
AOFF
AOFF
Cancel setting
A--4
Override every 4 days.
6. Regeneration cycle time step # 1
1-5.0
Ex: 5 min.
7. Regeneration cycle time step # 2
230.0
Ex: 30 min.
8. Regeneration cycle time # 3
3-5.0
Ex: 5 min.
9. Regeneration cycle time # 4
4-5.0
Ex: 5 min.
10. Regeneration cycle time # 5
5OFF
Not used
11. Meter type
Fxx.x
See the opposite chart
11.b Valve type
o--2
o--2
12. Tank in service
o-U1
o-U1
o-U2
13. Line frequency
LF50
LF50
LF60
Master programming mode is exited
12:05
Normal operation is resumed
3
)
2800 litres
AM
Adjustable
Meter size pusle
setting
Adjustable
2510SE
2750SE
2850SE
Adjustable
2900SE
2910SE
4600SE
Adjustable
5000SE
5600SE
8500SE
9000SE
9100SE
9500SE
In line Meter
8500SE, 9000SE, 9100SE
and 9500SE valves
Tank 1 in service
Tank 2 in service
Frequency: 50 Hz
Frequency: 60 Hz
ELECTRONIC SE
3/4"
F35.1
1"
F-2.1
1"1/2
F-1.0
2"
F--.5
2"
F--.5
3/4"
F35.1
3/4"
F34.6
3/4"
F35.1
3/4"
F34.9
3/4"
F-5.3
3/4"
F-5.3
1"1/2
F-1.0
F-21.0