] End of Shelf Life
) For Single Use Only
( Maximum Use Time 50 hours
: Name and address of Manufacturer
J Dispose of in accordance with local regulations
When stored as stated, the expected shelf life of the product is 5 years from date of manufacture. End of shelf life (use-by) date is marked on the product and
packaging. The original packaging is suitable for transporting the product throughout the European Union.
R = Reusable
NR = Non reusable (single shift use only)

TECHNICAL SPECIFICATION

3M combination lters generally protect against either single or multiple gas/vapour type(s) and against particulates.
Filter Type
Colour Code
A
Brown
B
Grey
E
Yellow
K
Green
Formaldehyde
Olive green
AX
Brown
Hg
Red
P
White
The 6000 Series gas/vapour lters are also classi ed, into one of two classes, depending on their capacity to remove
contaminants from the inhaled air
Gas/Vapour Filter Classes
Gas Filter Class
Maximum use concentration with 3M™ Half mask
10 x WEL or 1000 ppm (0.1% vol) whichever is lower
1
2
10 x WEL or 5000 ppm (0.5% vol) whichever is lower
Particulate Filter Class
Maximum use concentration with 3M™ Half mask
P3 R
20 x WEL
WEL = Workplace Exposure Limit
Filter Model
Classi cation
Type of Contaminant
3M™ 6091
A1P3 R
Organic vapours with boiling point >65°C (with good warning properties) as speci ed by the manufacturer and
particulates
3M™ 6092
A1B1E1K1P3
Combination organic vapours (boiling.point > 65°C (with good warning properties), inorganic gases, acid gases,
ammonia and formaldehyde up to 10 ppm and particulates
R + form
A2P3 R
3M™ 6095
Organic vapours with boiling point >65°C (with good warning properties) as speci ed by the manufacturer and
particulates
3M™ 6096
A1E1HgP3 R
Organic vapours with boiling point >65°C (with good warning properties) as speci ed by the manufacturer and
mercury vapour, chlorine, acid gases and particulates. If used for Hg, maximum use time = 50 hours.
3M™ 6098
AXP3 NR
Organic vapours with boiling point <65°C (with good warning properties) as speci ed by the manufacturer and
particulates
3M™ 6099
A2B2E2K2Hg
Organic vapours (b.pt>65°C (with good warning properties), inorganic gases, acid gases, ammonia, formaldehyde
up to 10 ppm, mercury vapour and particulates. If used for Hg, maximum use time = 50 hours.
P3 R + form
Note: AX lters are for single use only
The lter should not be used on a second shift even if these maximum usage times are not exceeded. When changing lters ensure that both lters are
replaced simultaneously.
Type of Contaminant
Organic vapours with boiling point >65°C (with good warning properties) as speci ed by the manufacturer
Inorganic Gases & Vapours (with good warning properties) as speci ed by the manufacturer
Acid Gases (with good warning properties) as speci ed by the manufacturer
Ammonia and Organic Ammonia derivatives (with good warning properties) as speci ed by the manufacturer
Formaldehyde vapour
Organic vapours with boiling point equal or less than 65°C (with good warning properties) as speci ed by the
manufacturer
Mercury vapour
Solid and non-volatile liquid aerosols
4
Maximum use concentration with 3M™ Full Face mask
20 x WEL or 1000 ppm (0.1% vol) whichever is lower in negative
pressure mode
20 x WEL or 5000 ppm (0.5% vol) whichever is lower in negative
pressure mode
Maximum use concentration with 3M™ Full Face mask
40 x WEL