Basic Operation
7
USB/RJ45 COMMUNICATION PORT: This port connects your UPS system to a
computer for automatic file saves and unattended shutdown in the event of a
power failure. Use with Tripp Lite's free downloadable PowerAlert
included USB/RJ45 cable. A PowerAlert CD may be included with your UPS system.
If so, insert the CD into the CD tray of your computer and follow the installation
instructions. If PowerAlert software did not come with your UPS system, you can
obtain the software free at www.tripplite.com.
Note: This connection is optional. The UPS system will work properly without this connection.
CAUTION! The USB/RJ45 port is not a phone or network port. Do not connect
a phone or network line to this port.
8
TEL/DSL PROTECTION JACKS: These jacks stop surges on a phone or fax line.
Using telephone (RJ11) cables, connect your wall jack to the UPS jack marked "IN."
Connect your equipment to the UPS jack marked "OUT." Make sure the equipment
you connect to the tel/DSL jacks is also protected against surges on the AC line.
Note: Connecting your equipment to these jacks is optional. Your UPS system will work
properly without this connection.
9
RESETTABLE CIRCUIT BREAKER: Protects your electrical circuit from overcurrent
draw from the UPS load. If this breaker trips, remove some of the load, then reset it
by pressing it in.
10
BATTERY BACKUP PROTECTED/SURGE PROTECTED OUTLETS: Provide both
battery backup and surge protection. Plug your computer, monitor and other critical
equipment into these outlets.
Note: do not plug laser printers into these outlets.
11
SURGE-ONLY PROTECTED OUTLETS: Provide surge and line noise protection, but
not battery backup. Plug equipment (such as a printer, scanner or fax machine) that
does not require battery backup during a utility power failure into these outlets.
12
BUILDING WIRING FAULT INDICATOR: This red LED illuminates if improper building
wiring is detected (usually an open ground connection). If a wiring fault is detected,
have the building wiring checked by a qualified electrician to assure the safety of all
connected equipment.
13
AC INPUT PLUG: Insert the plug into a compatible outlet to provide AC power for
the UPS system and connected equipment.
17-05-141-932716.indb 6
6
software and the
®
5/24/2017 3:17:37 PM