Ceramic
Bulb Socket
Machine
Screws
1. Preparation - Module Installations
Turn off the power at the circuit breaker.
Set the light fixture on a work surface with the circular opening
should be facing upward.
Remove the bar brackets from each side of the light housing by
removing the two machine screws.
In a 3/8" thick, 12" (30.5 cm) x 18" (45.7 cm) piece of plywood,
drill a 3-7/8" diameter (4" diameter if 3-7/8" hole saw is
unavailable) hole.
The centerpoint of the hole should be positioned 6" (15.2 cm)
from the end of the plywood and 6" (15.2 cm) from the side of
the plywood.
Attach the main unit to the plywood using a wood screw in each
corner.
1015878–2–B
Plywood
Sheet
6" (15.2cm)
Bar
Bracket
Wood
Screw
4