Operation
Adjustment of the open tray dispensers
Loosen both cylinder head screws with internal hexagon (1), but do not remove them completely.
Therefore use a hexagon wrench SW 0.3'' (8 mm).
Adjust the lateral stop edges to the desired level.
Screw the socket head screw tight.
To adjust the front stop edge, proceed as follows:
Unscrew the two counter nuts (2) from the setscrews. Therefore use an open-end wrench SW 17
Loosen the setscrews, but do not remove them completely. Therefore use a hexagon wrench 0.2'' (5
mm).
Pull out the front stop to the desired length.
Tighten the setscrews and secure with the counter nuts.
Set up the appliance again, so that it stands on all four wheels.
Adjusting the upper attaching point
To adjust the height of the dishwasher, the upper attaching point of the stacking platform can be set continu-
ously between 27.56 and 19.69'' (700 and 500 mm).
Figure 13
To adjust the upper attaching point, proceed as follows:
Remove the three screws (1) on the front and back of the cover of the spring case.
Pull out the frontal sheet with plastic stop beads.
Remove the cover of the spring case. The push bars remain on the cover of the spring case.
The height of the upper attaching point or the upper spring suspension is adjusted with two threaded rods
according to the spindle principle.
Turns to the right shift the attaching point downwards, turns to the left shift the attaching point upwards.
Figure 14
Turn both heads of the threaded rods (2) until the desired position of the upper stop is reached.
Therefore use an open-end wrench SW 17.
4330041_A0
OTA/47–36 | OTA/53–37 | OTA/58-33 | OTA/53–37 S | OTA/U-BW | OTA-E/BA-4xGN | TAG-1/53-37 | TA-2/53-37 | EBS-T/53-37
Adjust stop point
Heads of the threaded rods
Chapter 5
Page 25
Tray dispenser