HEATING SPECIFICATIONS
Nominal power
Efficiency nominal power
Emissions CO (13% O2) nominal power
Smoke mass nominal power
Reduced power
Efficiency reduced power
Emissions CO (13% O2) reduced power
Smoke mass reduced power
Maximum overheated smoke
Minimum draught
Time between refuellings (min/max)
Fuel consumption (min/max)
Hopper capacity
Heatable room dimensions *
Weight including packaging
Smoke duct diameter (A male)
Air intake duct diameter (B male)
* The heatable room dimensions are calculated on the basis of
pellets with an lhv of at least 4300 kcal/kg and home insulation in
compliance with Italian law 10/91, and subsequent changes toge-
ther with an expected heat output of 35 Kcal/m³ per hour.
* It is also important to consider the position of the stove in the
room to be heated.
N.B.
1) bear in mind that external devices may cause interference.
2) caution: live parts. Servicing and/or inspections must be carried out by qualified staff.

ELECTRICAL SPECIFICATIONS

Power supply
On/off switch
Average power consumption
Power consumption during ignition
Remote control frequency (optional extra)
Protection on mains power supply *
Electronic circuit board protection

SAFETY DEVICES:

THERMOCOUPLE:
On the smoke outlet. It measures the smoke temperature.
It controls the ignition, operating and shutdown stages according to
the parameters set.
AIR FLOW SENSOR:
On the intake duct. It trips when the flow of combustion air is not
correct, therefore causing low pressure problems in the smoke
circuit.
SAFETY THERMOSTAT:
It trips if the temperature inside the stove is too high.
It stops pellet loading, thus causing the stove to go out.
FUSE
* two fuses are inserted on the socket
behind the stove, fitted with a switch one
is functional and the other is spare.
* *
8,0
kW
89,2
%
75
ppm
5,5
g/s
3,4
kW
92,6
%
280
ppm
2,9
g/s
150
°C
12
Pa
7,5/18
hours
0,7/2,0
kg/h
15
kg
190
152
kg
80
mm
40
mm
230Vac +/- 10% 50 Hz
yes
150
W
400
W
infrared
2A, 250 Vac 5x20 Fuse
2A, 250 Vac 5x20 Fuse
SERIAL PORT
The Dealer can install an optional
on the AUX outlet (clean contact
on the pins) for controlling the
process of switching on and off (e.g. telephone remote,
local thermostat), located at the rear oh the stove. Can
be connected via special optional trestle (code 620550).
BACKUP BATTERY
A backup battery is found on the control board (3-Volt
CR 2032 battery).
Its malfunction is indicated with the following messages:
(not considered a defect but due to normal wear-and-
tear): ERR 1 - ERR 2.
For more detailed information, please contact the DEA-
LER who has performed the first 1st ignition.
- 16
-
SMOKE
THERMOCOUPLE
SPEED
ROOM
SENSOR
BACKUP
BATTERY
FLOW
SCREW FEEDER
SENSOR
MOTOR
IGNITION HEATING
SMOKE EXTRACTION
VENTILATION
MOTOR
ELEMENT
SAFETY
THERMOSTAT
VENTILATION
P/TEMP.
ADJUSTMENT
ADJUSTMENT
MAINS
Connessioni cavo combinatore telefon
pin 6
pin 7
Pin 6 e pin 7