SPECTRE Access UHF
Read only
Installation procedure
J6
J9
J7
DATA 2 / CLK2
DATA 3 / CLK3
DATA 4 / CLK4
The number of antennas, the number of channels and the communication protocol are configurable with the Ultrys V2 application or when the module is ordered.
TTL protocols (Wiegand & ISO2):
- ISO2 (Clock & Data) - Decimal (7 bytes max)
- Wiegand 26-bit
- Wiegand with LRC - Hexadecimal (12 bytes max) + LRC
- Wiegand without LRC - Hexadecimal (12 bytes max)
Serial protocols (RS232 & RS485): The structure of the frame can be configured with the following optional parameters (in gray):
1 byte
STX
Channel number + Tag Data*
0x02
- STX+ETX: add 0x02 (STX) and 0x03 (ETX) at the start /end of frame
- CR/LF: Carriage Return (0x0D + 0x0A) configurable separately
- LRC: Checksum (XOR of all previously bytes except STX)
- Data sent in: decimal or hexadecimal
- ASCII: if this option is activated, the data will be sent in ASCII mode (data size will be doubled).
- Non-significant zero: complete the tag data with not significant 0 to obtain the defined data size.
(Channel no. + 0 padding + tag data, etc.)
When the reader is switched on: the reader's red LED lights up. Reader initializing.
After initializing, the reader will look for a configuration tag for about 10 s, on antenna 1 (connected to RF port 1).
If no tag detected: the antenna LED flashes "color RFON" (200ms) (blue by default) / RFOFF (200ms).
•
•
If any tag is detected: the antenna LED displays the sequence "color RFON" (blue by default) / "color DETECTION" (orange by default) for 200ms
then LED OFF.
If a configuration tag is detected: the antenna LED displays the sequence « color RFON "(blue by default) / "color DETECTION" (orange by default)
•
for 200ms then LED OFF then the antenna LED gives the followings indications:
-
3 GREEN flashes (500ms ON; 200ms OFF): the configuration tag is taken into account
-
3 RED flashes (500ms ON; 200ms OFF): the regulation (region) of the configuration tag does not match to the regulation of the reader.
-
3 PURPLE flashes (500ms ON; 200ms OFF): the key of the configuration tag does match to the reader key.
-
5 RED flashes (500ms ON; 200ms OFF): the model of the reader of the configuration tag does match to the model of the reader.
The end of the start sequence is indicated by the flashing of the reader LEDs (red and green) 3 times (500ms ON; 500ms OFF).
© STid 2018 - 20 PA des Pradeaux FR13850 Gréasque - NI1127X01 - Page 2 sur 15 - Ed. 12/12/2018
UHF SPECTRE Access
Lecture seule
Notice d'installation
TTL / RS232 / RS485 / I/O Connection - SMA / SLA
Use this (on RS485 connection) when the distance of the data cable is near or over
100 m / 328.08 ft and the signal is weakened (polluted signals, frame errors etc.).
Micro USB connector for configuration purposes only
IN 1-2-3-4
OUT 1-2-3-4
V- opt
Low polarization potential of opto-coupled inputs and outputs
V+ opt
High polarization potential of opto-coupled inputs and outputs
DATA1
CLK1
ALIM
GND
1 byte + X bytes
1 byte
LRC
0x0y nn.....nn
End of line resistor RS485
TTL output level: +5V or Vin
4 opto-coupled inputs
4 opto-coupled outputs
Data or D0 Channel 1 or Tx (
RS232)
Clock or D1 Channel 1 or Rx (
RS232) or
Data/Clock or D0/D1 Channel 2
Data/Clock or D0/D1 Channel 3
Data/Clock or D0/D1 Channel 4
Power supply
GND
Configuration - SMA / SLA
1 byte
1 byte
1 byte
CR
LF
ETX
0x0D
0x0A
0x03
Start Sequence - SMA / SLA
Acceso UHF SPECTRE
Solo lectura
Manual de instalación
or L+ (
RS485)
L- (
RS485)
.
US
FR
ES